Engineered for the best signal visibility

U1881A Summary of contents

Page 1

... Agilent Technologies Infi niiVision 7000B Series Oscilloscopes Data Sheet Engineered for the best signal visibility ...

Page 2

If you haven’t purchased an Agilent scope lately, why should you consider one now? Oscilloscopes are visual tools and larger, high-resolution displays have become increasingly important as general purpose scopes need more space to display digital and serial signals in ...

Page 3

What gives the Infi niiVision 7000B Series the best signal visibility? 1. Biggest display Oscilloscopes are visual tools and larger, high-resolution screens make the product better. Bigger displays have become increasingly important as general purpose scopes need more space to ...

Page 4

Your design has analog, digital and serial signals ... shouldn’t your scope? Analog GHz bandwidth and GSa/s sample rate Digital: 16 digital timing channels with mixed signal triggering Serial: Hardware-accelerated decode and 2 2 ...

Page 5

Other useful features Dedicated Front Panel Key Simply press the dedicated front panel Search Key and enter a variety of specifi c search criteria High resolution mode. Offers bits of vertical resolution. This is accomplished by serially ...

Page 6

Why does a fast update rate matter? While bandwidth, sample rate and memory depth are key criteria for deciding which scope to purchase, an equally important characteristic is update rate. What is update rate? Update rate is how many waveforms ...

Page 7

How update rate affects signal visibility Capturing random and infrequent events on an oscilloscope is all about statistical probabilities. The key to improving the probability of capturing a signal anomaly is to minimize dead-time and take more pictures of the ...

Page 8

Software applications Mask testing uncovers an infrequent signal anomaly. Use segmented memory to optimize available memory. 2 View on-screen serial decode packet. Trigger on and decode RS-232/UART transmission. 8 Mask testing (N5455A or Option LMT) Agilent’s ...

Page 9

Software applications Trigger on and decode CAN serial packets. Time-correlated display of the FlexRay physical layer signal with protocol decoding. On-screen serial decode of an SPI packet Time-correlated display of the MIL-STD 1553 physical layer signal with protocol decoding. Debug ...

Page 10

... Infi niiVision 7000B Series oscilloscopes. 10 Power application (U1881A) Need to make power measurements with your scope? Agilent’s power application provides a full suite of power measurements that run connected to an Infi niiVision 7000B Series oscilloscope. Make more accurate power supply effi ciency measurements by using an U1880A deskew fi ...

Page 11

... Included with all MSO models is a logic probe with 2x8 flying leads (includes 20 IC clips and five ground leads) For more comprehensive information, refer to the Agilent 5000, 6000 and 7000 Series Oscilloscopes Probes and Accessories Data Sheet (with Agilent lit number 5968-8153EN). ...

Page 12

Connectivity The 7000 B Series scopes come with the most comprehensive connectivity tools in their class. LXI class C LAN eXtensions for Instrumentation (LXI standards-based architecture for test systems. By specifying the interaction of system components, LXI enables ...

Page 13

Agilent Infi niiVision Portfolio Agilent’s Infi niiVision lineup includes 2000X, 3000X, 6000, and 7000B Series oscilloscopes. These share a number of advanced hard- ware and software technology blocks. Use the following selection guide to determine which scope best matches your ...

Page 14

Agilent Infi niiVision 7000B Series oscilloscopes: Engineered for the best signal visibility 12.1” large display makes it easier to view analog, digital and serial signals. High-resolution color display with XGA resolution and 256 levels of intensity reveals subtle details that ...

Page 15

Dedicated front panel controls make it easy to access the most common scope controls, including vertical and horizontal scaling. Search and Navigate front panel controls make it easy to fi view specifi c signal activity. Quickly pan and ...

Page 16

Performance characteristics Acquisition: scope channels Sample rate Memory depth Standard Vertical resolution Peak detection Averaging High resolution mode Filter Acquisition: digital channels (7000B Series MSO or MSO-upgraded 7000B Series DSO) Sample rate Maximum input frequency Memory depth Standard Standard Vertical ...

Page 17

Performance characteristics Vertical system: scope channels Scope channels Bandwidth (–3 dB)* AC coupled Calculated rise time (=0.35/bandwidth) Single-shot bandwidth Range 1 Maximum input Offset range Dynamic range Input impedance Coupling BW limit Channel-to-channel isolation Standard probes Probe ID * Denotes ...

Page 18

Performance characteristics Vertical system: scope channels (continued) ESD tolerance Noise, RMS, input shorted DC vertical gain accuracy vertical offset accuracy 1 Single cursor accuracy 1 Dual cursor accuracy* * Denotes warranted specifications, all others are typical. Specifications are ...

Page 19

Performance characteristics Horizontal Range Resolution Time scale accuracy* Vernier Delay range Analog delta-t accuracy Logic delta-t accuracy Modes XY Reference positions Segmented memory re-arm time Trigger system Sources Modes Holdoff time Trigger jitter * Denotes warranted specification. Specifications are valid ...

Page 20

Performance characteristics Trigger system (continued) Selections Edge Pattern Pulse width TV Sequence CAN FlexRay LIN USB SPI RS-232/UART Duration MIL-STD 1553 20 (continued) Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I ...

Page 21

Performance characteristics Trigger system (continued) Nth edge burst Autoscale Scope channel triggering Range (internal) Sensitivity* Coupling Digital (D15 - D0) channel triggering (7000B Series MSO or MSO-upgraded 7000B Series DSO) Threshold range (user defined) Threshold accuracy Predefined thresholds External (EXT) ...

Page 22

Performance characteristics Display system Display Throughput of scope channels Resolution Controls Built-in help system Real-time clock Measurement features Automatic measurements Voltage (scope channels only) Time Counter Threshold definition Cursors Waveform math Measurement statistics Precision Mode 22 (continued) 12.1-inch (255 mm ...

Page 23

Performance characteristics FFT Points Source of FFT Window Noise floor Amplitude Frequency resolution Maximum frequency Storage Save/recall (non-volatile) Storage type and format I/O Standard ports Max transfer rate Supported printers via USB General characteristics Physical size (WxHxD) Weight Probe comp ...

Page 24

Performance characteristics General characteristics (continued) Trigger out 10 MHz ref in/out Kensington lock Power requirements Line voltage range Line frequency Power usage Environmental characteristics Ambient temperature Humidity Altitude Vibration Shock Pollution degree Typical operator noise Indoor use Other Measurement categories ...

Page 25

... MSO7054B 500 MHz DSO7104B 1 GHz MSO7104B 1 GHz Accessories included: Model number Standard 3-year warranty Standard probe 100 MHz : 10074D (default), N2871A (optional – as option 002) 350 MHz – 1GHz : 10073D (default), N2873A (optional – as option 002) 16 channel flying lead set logic probe (two pods with eight channels each) ...

Page 26

... FPGA dynamic probe for Xilinx (MSO models only) N5434A FPGA dynamic probe for Altera (MSO models only) B4610A Offline viewing and analysis of MSO/DSO data U1881A Power measurement and analysis application E2690B ASA’s Oscilloscope tools Other measurement options Option number – user installed Option number – ...

Page 27

... Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications 27 ...

Page 28

... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2011 Printed in USA, February 15, 2011 5990-4769EN ...