N5181AK-UNT AGILENT TECHNOLOGIES, N5181AK-UNT Datasheet

N5181 Analog Signal Generator

N5181AK-UNT

Manufacturer Part Number
N5181AK-UNT
Description
N5181 Analog Signal Generator
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of N5181AK-UNT

Accessory Type
AM, FM, Phase Modulation
For Use With
N5181A-501, N5181A-503, N5181A-506 MXG RF Analog Signal Generators
Lead Free Status / RoHS Status
na
Agilent N5181A
MXG
and N5161A MXG ATE
s
Analog
Signal Generator
Optimized for
Data Sheet
performance and speed
• Fast switching speeds
• Simplified self-maintenance
• High output power

N5181AK-UNT Summary of contents

Page 1

Agilent N5181A and N5161A MXG ATE Analog Signal Generator MXG s Optimized for Data Sheet performance and speed • Fast switching speeds • Simplified self-maintenance • High output power ...

Page 2

Table of Contents 2 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 3

Definitions Specification (spec): Represents warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range °C, unless otherwise stated, and after a 45 minute warm-up period. ...

Page 4

Frequency 4 Range Option 501 100 kHz to 1 GHz Option 503 100 kHz to 3 GHz Option 506 100 kHz to 6 GHz Minimum frequency 100 kHz Resolution 0.01 Hz Phase offset Adjustable in nominal 0.01° increments 2 Frequency ...

Page 5

Accuracy ± aging rate ± temperature effects ± line voltage effects I nternal time base reference oscillator aging rate ≤ ± 5 ppm/10 yrs, < ± 1 ppm/yr (nom) Temperature effects ± 1 ppm ( °C) (nom) Line ...

Page 6

Amplitude 6 1 Output power Minimum output power –110 dBm 2 with Option 1EQ –127 dBm Maximum output power Range Standard 100 kHz to 250 kHz +13 dBm > 250 kHz to 50 MHz +13 dBm > 50 MHz to ...

Page 7

Switching speed Type Standard SCPI mode ≤ (typ) List/Step sweep mode ≤ (typ) 3 Absolute level accuracy [ALC on] 4 +23 to –60 dBm < –60 to –110 dBm 5 100 kHz to 250 ...

Page 8

Level accuracy at –110 dBm 1 0.8 0.6 0.4 0.2 0 –0.2 –0.4 –0.6 –0.8 –1 0 1000 2000 3000 Frequency (MHz) 8 Absolute level accuracy [ALC off, relative to ALC on] 1 0.8 0.6 0.4 0.2 0 –0.2 –0.4 ...

Page 9

Amplitude repeatablity +5 dBm ALC on 0.5 0.4 0.3 0.2 0.1 0 –0.1 –0.2 –0.3 –0.4 –0 Elapsed time (minutes) Repeatability measures the ability of the instrument to return to a given power setting after a random ...

Page 10

ALC linearity 850 MHz, CW, relative to 0 dBm 0.3 0.2 0.1 0 –0.1 –0.2 –0.3 –20 –15 –10 –5 Amplitude (dB) ALC linearity 2200 MHz, CW, relative to 0 dBm 0.3 0.2 0.1 0 –0.1 –0.2 –0.3 –20 –15 ...

Page 11

Spectral Purity User flatness correction Number of points 3201 Number of tables Dependent on available free memory in instrument; 10000 maximum Entry modes USB/LAN direct power meter control, LAN to GPIB and USB to GPIB, remote bus and manual USB/GPIB ...

Page 12

AM noise at 1 GHz -60.00 -70.00 -80.00 -90.00 -100.0 -110.0 -120.0 -130.0 -140.0 -150.0 -160.0 -170.0 -180.0 10 100 1k 10k Residual FM [CW mode, 300 kHz BW, CCITT, rµs] 1 Harmonics [CW mode, output ...

Page 13

Analog Modulation 1 Frequency modulation (Option UNT) Max deviation MHz (nom) Resolution 0.1% of deviation or 1 Hz, which ever is greater (nom) Deviation accuracy [1 kHz rate, deviation kHz] < ±2% + ...

Page 14

Internal analog modulation source (Single sine wave generator for use with AM, FM, phase modulation. Requires Option UNT) Waveform Sine Rate range 0 MHz (tuneable to 3 MHz) Resolution 0.1 Hz Frequency accuracy Same as RF ...

Page 15

Td Video delay (variable) Sync Tw Video pulse width (variable) output Tp Pulse period (variable delay Video Trf RF pulse width output Tf RF pulse fall time Tr RF pulse rise time Vor Pulse overshoot RF pulse Vf ...

Page 16

... General Characteristics 16 Remote programming Interfaces Control languages Compatibility languages supporting 100% of commonly used commands Agilent Technologies Aeroflex Incorporated Rohde & Schwarz Power requirements Operating temperature range Storage temperature range Operating and storage altitude Environmental stress Safety EMC Memory Security (Option 006) ...

Page 17

... Agilent has verified that the stability of this product's architecture justifies a longer calibration interval of 3 years. ISO compliant The Agilent N5181A MXG is manufactured in an ISO-9001 registered facility in concurrence with Agilent Technologies’ commitment to quality. 1 Front panel connectors 2 RF output Outputs the RF signal via a precision N type female connector ...

Page 18

... Instrument security 1ER Flexible reference input ( MHz) 1EM Move RF output to rear panel UK6 Commercial calibration certificate with test data 099 Expanded license key upgradeability Accessories 1CM Rackmount kit 1CN Front handle kit 1CP Rackmount and front handle kit 1CR Rack slide kit ...

Page 19

Archive Section Frequency Minimum frequency 100 kHz 2 Output power Range (for serial number 100 kHz to 250 kHz prefix 4742xxxx) > 250 kHz to 2.5 GHz –110 to +13 dBm > 2.5 to 3.0 GHz > 3.0 to 4.5 ...

Page 20

Maximum available output power Maximum available output power 1000 1000 2000 2000 Frequency (MHz) Frequency (MHz) SWR ≤ 2.1 ...

Page 21

Spectral Purity (for serial numbers lower than 4818xxxx) 1 Harmonics [CW mode, output level < 4 dBm] 250 kHz to 3 GHz < –30 dBc > 3 GHz to 6 GHz < –44 dBc (typ) 1 Nonharmonics [CW mode], > ...

Page 22

... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2006-2011 Printed in USA, March 9, 2011 5989-5311EN ...