HCTEK54 Tektronix, HCTEK54 Datasheet

no-image

HCTEK54

Manufacturer Part Number
HCTEK54
Description
HARD TRANSIT CASE
Manufacturer
Tektronix
Type
Oscilloscope hard transit caser
Datasheet

Specifications of HCTEK54

Accessory Type
Hard Transit Case
Color
Black
Used With
MSO5000/DPO5000/MSO4000B/DPO4000B Series Oscilloscopes
For Use With
MSO/DPO4000B & MSO/DPO5000 Series Mixed Signal Oscilloscopes
Lead Free Status / RoHS Status
na
Mixed Signal Oscilloscopes
MSO4000B, DPO4000B Series Data Sheet
Features & Benefits
Key Performance Specifications
Ease of Use Features
1 GHz, 500 MHz, 350 MHz Bandwidth Models
4 Analog Channel Models
16 Digital Channels (MSO Series)
Up to 5 GS/s Sample Rate on All Channels
20 Megapoint Record Length on All Channels
>50,000 wfm/s Maximum Waveform Capture Rate
Standard Passive Voltage Probes with Less than 4 pF Capacitive
Loading and 500 MHz or 1 GHz Analog Bandwidth
Suite of Advanced Triggers
Wave Inspector
Search of Waveform Data
41 Automated Measurements, Waveform Histograms, and FFT Analysis
for Simplified Waveform Analysis
TekVPI
Probes for Automatic Scaling and Units
10.4 in. (264 mm) Bright XGA Color Display
Small Footprint and Lightweight – Only 5.8 in. (147 mm) deep and 11 lb.
(5 kg)
®
Probe Interface supports Active, Differential, and Current
®
Controls provide Easy Navigation and Automated
Connectivity
Optional Serial Triggering and Analysis
Mixed Signal Design and Analysis (MSO Series)
Optional Application Support
Feature-rich Tools for Debugging Mixed
Signal Designs
With the MSO/DPO4000B Mixed Signal Oscilloscope Series, you can
analyze up to 20 analog and digital signals with a single instrument to
quickly find and diagnose problems in complex designs. Bandwidths up to
1 GHz and a minimum of 5X oversampling on all channels ensure you have
the performance you need to see fast-changing signal details. To capture
long windows of signal activity while maintaining fine timing resolution, the
MSO/DPO4000B Series offers a deep record length of 20M points standard
on all channels.
With Wave Inspector
serial and parallel bus analysis, limit and mask testing, and automated
power analysis – the MSO/DPO4000B Oscilloscope Series from Tektronix
provides the feature-rich tools you need to simplify and speed debug of
your complex design.
Two USB 2.0 Host Ports on the Front Panel and Two on the Rear Panel
for Quick and Easy Data Storage, Printing, and Connecting a USB
Keyboard
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or
Direct Printing to a PictBridge
Integrated 10/100/1000BASE-T Ethernet Port for Network Connection
and Video Out Port to Export the Oscilloscope Display to a Monitor or
Projector
Automated Serial Triggering, Decode, and Search Options for I
SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART,
MIL-STD-1553, and I
Automated Triggering, Decode, and Search on Parallel Buses
Per-channel Threshold Settings
Multichannel Setup and Hold Triggering
MagniVu™ High-speed Acquisition Provides 60.6 ps Fine Timing
Resolution on Digital Channels
Power Analysis
Limit and Mask Testing
HDTV and Custom Video Analysis
®
controls for rapid waveform navigation, automated
2
S/LJ/RJ/TDM
®
-compatible Printer
2
C,

HCTEK54 Summary of contents

Page 1

... With Wave Inspector controls for rapid waveform navigation, automated ® serial and parallel bus analysis, limit and mask testing, and automated power analysis – the MSO/DPO4000B Oscilloscope Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design. C, ...

Page 2

... Capture – Triggering on a specific transmit data packet going across an RS-232 bus. A complete set of triggers, including triggers for specific serial packet content, ensures you quickly capture your event of interest ...

Page 3

... For extended analysis, National Instrument’s LabVIEW SignalExpress™ Tektronix Edition provides over 200 built-in functions including time and frequency domain analysis, data logging, and customizable reports. www.tektronix.com ...

Page 4

... Once again, turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way. 4 www.tektronix.com Search step 1: You define what you would like to find. Search step 2: Wave Inspector automatically searches through the record and marks each event with a hollow white triangle ...

Page 5

... One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display. The MSO4000B Series has color-coded digital traces, displaying ones in green and zeros in blue. www.tektronix.com 5 ...

Page 6

... The P6616 MSO probe offers two eight-channel pods to simplify connecting to your device. The MSO4000B Series simplifies channel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard ...

Page 7

... Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Previous (←) and Next (→) buttons on the front panel. S/LJ/RJ/TDM only), or ASCII (USB, 2 www.tektronix.com 7 ...

Page 8

... A robust set of telecommunications and computer standards are provided to test for compliance to a standard. 8 www.tektronix.com Limit Test showing a mask created from a golden waveform and compared against a live signal. Results showing statistical information about the test are displayed. Additionally, custom masks can be created and used for characterizing signals. Tailor a test to your specifi ...

Page 9

... The TekVPI interface enables direct attachment of current probes without requiring a separate power supply. TekVPI probes can be controlled remotely through USB, GPIB, or LAN, enabling more versatile solutions in ATE environments. www.tektronix.com 9 ...

Page 10

... Windows PC. NI LabVIEW SignalExpress Tektronix Edition enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming ...

Page 11

... MHz Maximum frequency sine wave that can accurately be reproduced as a logic square wave. Requires the use of a short ground extender on each channel. This is the maximum frequency at the minimum swing amplitude. Higher toggle rates can be achieved with higher amplitudes. www.tektronix.com 5 GS ...

Page 12

... C (Optional) Trigger on Start, Repeated Start, Stop, Missing ACK, Address ( bit), Data, or Address and Data SPI (Optional) Trigger on SS active, MOSI, MISO, or MOSI and MISO on SPI buses Mb/s 12 www.tektronix.com Trigger Level Range Characteristic Description Any Channel ±8 divisions from center of screen External ± ...

Page 13

... Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error Mb/s (Optional) MIL-STD-1553 Trigger on Sync, Word Type, Parity Error. Data can be further specified to trigger on ≤, <, =, >, ≥, ≠ a specific data value, or inside or outside of (Optional) a range. Mixed Signal Oscilloscopes — MSO4000B, DPO4000B Series www.tektronix.com 13 ...

Page 14

... Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math Types – Vertical, Horizontal Waveform Histogram Waveform Count, Hits in Box, Peak Hits, Median, Measurements Max, Min, Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3 14 www.tektronix.com S/LJ/RJ is 12.5 Mb/s 2 Waveform Math Characteristic Arithmetic Math Functions FFT ...

Page 15

... Software Software Description NI LabVIEW A fully interactive measurement software environment SignalExpress Tektronix optimized for the MSO/DPO4000B Series, enables Edition you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming ...

Page 16

... GHz models), Front Cover (200-5130-xx), User Manual (071-2810-xx), Documentation CD (063-4300-xx), OpenChoice SignalExpress™ Tektronix Edition Software, Calibration Certificates document measurement traceability to National Metrology Institute(s) – the Quality System this product is manufactured in is ISO9001 registered, power cord, accessory bag (016-2029-xx) and a three-year warranty ...

Page 17

... Limit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask testing using custom or standard telecommunications or computer masks HDTV and Custom (nonstandard) Video Triggering Module www.tektronix.com ...

Page 18

... Software (Full Version) FPGAView-xx MSO Support for Altera and Xilinx FPGAs TPA-BNC TekVPI-to-TekProbe BNC Adapter TEK-USB-488 GPIB-to-USB Adapter ACD4000B Soft Transit Case HCTEK54 Hard Transit Case (Requires ACD4000B) RMD5000 Rackmount Kit TEK-DPG Deskew Pulse Generator 067-1686-xx Deskew Fixture Warranty Three-year warranty covering all parts and labor, excluding probes. ...

Page 19

... Mixed Signal Oscilloscopes — MSO4000B, DPO4000B Series www.tektronix.com 19 ...

Page 20

... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...