104STA-N5 EDWARDS SIGNALING PRODUCTS, 104STA-N5 Datasheet - Page 2

XENON BEACON LIGHT, 120V, 120mA

104STA-N5

Manufacturer Part Number
104STA-N5
Description
XENON BEACON LIGHT, 120V, 120mA
Manufacturer
EDWARDS SIGNALING PRODUCTS
Datasheet

Specifications of 104STA-N5

Light Source
Xenon
Current Rating
120mA
Bulb Diameter
82.6mm
Length
98.4mm
Ip/nema Rating
NEMA 4X
Peak Reflow Compatible (260 C)
No
Supply Voltage
120V
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Maintenance
Cleaning
The module lens exterior surfaces should be periodically cleaned
with a soft clean cloth using water and a mild detergent to main-
tain optimum light visibility. Disconnect power before cleaning.
Lamp Replacement
1. Conduit Mounted Modules: Disconnect wiring and, if
2. Remove (4) screws securing the lens to the base from bottom
3. Replace halogen lamp or strobe tube as follows (Figure 3):
P-047550-1848 ISSUE 6
To avoid risk of injury, install lens before energizing
the unit.
To avoid the risk of injury, do not start any
maintenance when unit is energized.
To prevent electrical shock, disconnect all power
and wait five (5) minutes for stored energy in strobe
modules to dissipate before starting work on unit.
necessary, unscrew base from conduit (Figure 1).
Panel Mounted Modules: Disconnect wiring and remove
locking nut securing the base to the panel (Figure 2).
of base (Figure 3) and remove lens.
a.
Halogen Lamp: Grasping the base of the halogen lamp
(Do not touch actual halogen lamp envelope), push
the halogen lamp down while turning counterclockwise.
Then, pull the lamp directly upward to remove from the
socket.
Strobe Tube: Grasping the base of the strobe tube (Do
not touch actual strobe tube glass), pull directly upward
to remove the strobe tube from the socket.
WARNINGS
Figure 2. Panel Mounting
4. Replace lens on base and secure with (4) screws removed in
b.
step 2.
Grasping the base of the new lamp or strobe tube, insert
in the socket.
Figure 1. Conduit Mounting (3/4" Shown)
Figure 3. Lamp Replacement

Related parts for 104STA-N5