HUL200 COVER XP POWER, HUL200 COVER Datasheet - Page 4

COVER, PSU

HUL200 COVER

Manufacturer Part Number
HUL200 COVER
Description
COVER, PSU
Manufacturer
XP POWER
Datasheet

Specifications of HUL200 COVER

Accessory Type
Cover
Svhc
No SVHC (18-Jun-2010)
External Depth
172.7mm
External Height
42.1mm
External Length / Height
42.1mm
External Width
96.5mm
Body Material
Steel
Enclosure Material
Steel
For Use With
HUL200
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Models and Ratings
Notes
1. Use part number UL300-XX for product without harmonic correction. e.g. UL300-10.
2. Output 4 is floating. It can be connected externally for positive or negative output.
3. Total output power for HUL300-12,13,14,18 models is 200 W convection-cooled, 300 W with 30 CFM forced air cooling.
4. Total output power for all other HUL300 models is 150 W convection-cooled, 300 W with 30 CFM forced air cooling.
5. Tolerance 5% all outputs, except single output units - tolerance 2%.
Mechanical Details
All dimensions are in inches (mm). Tolerance: 0.02 (0.5) max. Weight: 2.20 lbs (1.0 kg) approx.
Notes
1. Input connector P1 mates with Molex housing 09-91-0500 and Molex 2478/2578/8818 series crimp terminal.
2. Output connector P2 mates with Molex housing 09-91-1400 and Molex 2478/2578/8818 series crimp terminal.
3. Fan connector mates with JST housing XHP-2 and JST SXH-002T-P0.6 crimp terminals. Multiple outputs only.
4. Signals connector P3 mates with JST housing XHP-6 and JST SXH-002T-P0.6 crimp terminals.
5. Covered versions are available,
6. Output is turned off by taking the Remote On/Off pin low (connect to Return).
7. DC OK is a open collector output. Low = normal operation.
8. Cable harnesses with
9. Covers are available separately. Order part HUL300
10. Max penetration of screws 0.12” (3.0 mm).
Voltage
Available from Farnell. See pages 204-206.
+5.0 V
+5.0 V
+5.0 V
+5.0 V
+5.0 V
+5.0 V
+5.0 V
+5.0 V
12.0 V
15.0 V
24.0 V
48.0 V
Nom
add suffix: ‘-C’ to model number for cover only, dimensions: 4.25” x 8.00” x 2.16” (108.0 x 203.2 x 54.8 mm)
add suffix: ‘-FC’ to model number for fan cover, dimensions: 4.25” x 8.00” x 3.00” (108.0 x 203.2 x 75.7 mm).
HUL300 LOOM-T for triple output models or HUL300 LOOM-Q for quad output models. For mating connectors only, order part HUL300 CON KT†.
3.3 V
5.0 V
(203.2)
8.00
Output 1
(190.5)
7.50
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
Min
0.25 (6.35)
(147.6)
5.81
Current
(25.4)
1.00
11.81” (
60.00 A
60.00 A
25.00 A
20.00 A
12.50 A
30.00 A
30.00 A
30.00 A
30.00 A
30.00 A
30.00 A
30.00 A
30.00 A
6.25 A
Max
2.00 (50.8)
300 mm) wire available, order part number HUL300 LOOM-S for single output models, HUL300 LOOM-D for dual output models,
+12.0 V
+15.0 V
+24.0 V
+12.0 V
+15.0 V
+12.0 V
+24.0 V
+15.0 V
Voltage
Nom
(27.8)
1.09
0.25
(6.4)
(177.8)
(12.7)
Output 2
7.00
0.50
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
Min
COVER†
Current
1
12.5 A
10.0 A
10.5 A
10.0 A
M4 x 0.7 NUT FASTENER
Max
6.3 A
8.0 A
4.3 A
7.4 A
or HUL300
(12 PLACES)
4.25 (108.0)
2.50 (63.5)
L N G
P2
Voltage
-12.0 V
F/COVER†
-5.0 V
-5.0 V
nom
P1
14
PIN 1
FAN
Output 3
P3
for Fan Cover.
0.0 A
0.0 A
0.0 A
Min
Current
2.0 A
2.0 A
2.0 A
Max
F 12.0 V
F 15.0 V
F 12.0 V
F 12.0 V
F 15.0 V
Voltage
nom
Pin
Pin
10
11
12
13
14
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
Output 4
Power Fail Detect
Remote On/Off
Single Output
Single Output
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
Min
Output 1
Output 1
Output 1
Output 1
Output 1
Output 1
Output 1
DC OK
Return
Return
Return
Return
Return
Return
Return
Return
Return
Fan +
Current
(2)
P2 Connector
P3 Connector
2.0 A
2.0 A
2.0 A
2.0 A
2.0 A
Max
(6)
HUL300
Power Fail Detect
Remote On/Off
Output 4 Return
HUL300-10-1
HUL300-10
HUL300-12
HUL300-13
HUL300-14
HUL300-18
HUL300-23
HUL300-24
HUL300-25
HUL300-31
HUL300-32
HUL300-40
HUL300-45
HUL300-46
Multi Output
Multi Output
Output 3
Output 1
Output 1
Output 1
Output 1
Output 2
Output 2
Output 4
DC OK
Number
Return
Return
Return
Return
Return
Return
Return
Return
Model
17-Apr-07
(7)
(1)
(6)