HFBR-5903 Avago Technologies US Inc., HFBR-5903 Datasheet - Page 9

no-image

HFBR-5903

Manufacturer Part Number
HFBR-5903
Description
Fiber Optics, Transceiver Module
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HFBR-5903

Data Rate Max
125Mbps
Wavelength Typ
1300nm
Connector Type
MT-RJ
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HFBR-5903E
Manufacturer:
HRS
Quantity:
6 000
Part Number:
HFBR-5903E
Manufacturer:
AGILENT
Quantity:
20 000
Regulatory Compliance Table
Electrostatic Discharge (ESD)
There are two design cases in which immunity to ESD
damage is important.
The first case is during handling of the transceiver prior
to mounting it on the circuit board. It is important to
use normal ESD handling precautions for ESD sensitive
devices. These precautions include using grounded
wrist straps, work benches, and floor mats in ESD
controlled areas.
DIMENSIONS IN MILLIMETERS (INCHES)
9
Feature
Electrostatic Discharge
(ESD) to the Electrical Pins
Electrostatic Discharge
ESD) to the MT-RJ Receptacle
Electromagnetic
Interference (EMI)
Immunity
Eye Safety
Figure 10. Recommended Panel Mounting
(0.425±0.004)
10.8 ±0.1
(0.55)
13.97
MIN.
(TOP OF PCB TO
(0.01 ±0.004)
MIL-STD-883C
Method 3015.4
Test Method
Variation of
IEC 801-2
FCC Class B
CENELEC CEN55022
VCCI Class 2
Variation of IEC 801-3
IEC 825 Issue 1 1993:11
Class 1
CENELEC EN60825 Class 1
BOTTOM OF
0.25 ±0.1
OPENING)
(0.386±0.004)
9.8 ±0.1
(0.15 )
3.8
(0.039 )
(0.589)
14.79
1
Performance
Meets Class 2 (2000 to 3999 Volts).
Connector Receptacle is contacted by a Human Body Model probe.
circuit card without a chassis enclosure.
chassis enclosure.
Compliant per Avago Technologies testing under single fault conditions.
Withstand up to 2200 V applied between electrical pins.
Typically withstand at least 25 kV without damage when the MT-RJ
Transceivers typically provide a 10 dB margin to the noted standard limits
when tested at a certified test range with the transceiver mounted to a
Typically show no measurable effect from a 10 V/m field swept from 10 to
450 MHz applied to the transceiver when mounted to a circuit card without a
TUV Certification: LED Class 1
The second case to consider is static discharges to the
exterior of the equipment chassis containing the
transceiver parts. To the extent that the MT-RJ
connector is exposed to the outside of the equipment
chassis it may be subject to whatever ESD system level
test criteria that the equipment is intended to meet.