G310R210 Red Lion Controls, G310R210 Datasheet

no-image

G310R210

Manufacturer Part Number
G310R210
Description
TFT SVGA Indoor USB Host Isolated Comms
Manufacturer
Red Lion Controls
Type
Color Graphicr
Datasheet

Specifications of G310R210

Brand/series
G3 Series
Communication
Extensive List of Industrial Devices
Dimensions
12.83 × 9.50
Display Size
10.4 In.
Memory
32 Mb Flash
Mounting Type
Panel
Port Style
RS-232/422/485 and Ethernet
Primary Type
Operator Interface
Resolution
800 × 600
Resolution, Display
800 × 600
Size
10.4" Color TFT
Special Features
Web-Server, UL and Class I Div.2
User Interface
Touchscreen
Voltage, Supply
24 V
Configuration Is Stored In Non-volatile Memory
4 Mbyte Flash for G306M
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
PLCs, Motor Drives and other Industrial Devices
PROCESS CONTROL EQUIPMENT
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
GENERAL DESCRIPTION
expected from high-end units with a very affordable price. It is built around a
high performance core with integrated functionality. This core allows the G310
to perform many of the normal features of the Paradigm range of Operator
Interfaces while improving and adding new features.
high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100
Base-TX communications. In addition, the G310 features USB for fast downloads
of configuration files and access to trending and data logging. A CompactFlash
socket is provided so that Flash cards can be used to collect your trending and data
logging information as well as to store larger configuration files.
allows a user to easily view and enter information. Users can enter data through
the touchscreen or front panel 8-button keypad.
CONTENTS OF PACKAGE
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.
MODEL G310C2/R2/S2 - 10.4" COLOR TOUCHSCREEN
C C
The G310 Operator Interface Terminal combines unique capabilities normally
The G310 is able to communicate with many different types of hardware using
In addition to accessing and controlling of external resources, the G310
- G310 Operator Interface.
- Panel Gasket.
- This hardware bulletin.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.
All safety related regulations, local codes and instructions that appear in the
Do not use the controller to directly command motors, valves, or other
installation and operation of the unit.
Read complete instructions prior to
U L
R
CAUTION: Risk Of Danger.
WARNING - EXPLOSION HAZARD - SUBSTITUTION
OF ANY COMPONENT MAY IMPAIR SUITABILITY
FOR CLASS I, DIVISION 2
US LISTED
US LISTED
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
43NH
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
CAUTION: Risk of electric shock.
 CONFIGURED USING CRIMSON
 UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS
 10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS
 USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM A
 UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE MEMORY
 COMPACTFLASH
 10.4-INCH TFT 32K VGA 640X480 PIXEL LCD OR SVGA 800X600 LCD
 OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE
 8-BUTTON KEYPAD FOR ON-SCREEN MENUS
 THREE FRONT PANEL LEDS
 POWER UNIT FROM 24VDC ±20% SUPPLY
 RESISTIVE ANALOG TOUCHSCREEN
1
LATER)
(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1 RS-422/485
ON OPTIONAL COMMUNICATIONS CARD)
AND HOST WEB PAGES (2
PC OR FOR DATA TRANSFERS TO A PC
(32MBYTE FLASH)
ORDERING INFORMATION
CompactFlash is a registered trademark of CompactFlash Association.
MODEL NO.
1
2
3
4
5
6
7
8
G3PBDP Profibus DP Optional Communication Card
G3GSM
G3FILM
SFCRM
Contact your Red Lion distributor or visit our website for complete selection.
Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete
Battery type is lithium coin type CR2025
For use in non-hazardous locations only.
LED backlight is not field replaceable.
Use this part number to purchase Crimson on CD with a printed manual, USB
cable, and RS-232 cable. Otherwise, download for free from www.redlion.net.
separately if needed.
details.
Industrial grade two million write cycles. SMART Modular Technologies model
SG9CF (UL Listed Directory Category NWGQ).
G3CN
G3DN
Antenna (G3QANT00) is NOT included with the card. Must be purchased
G3CF
G3RS
G310
CBL
DR
10.4" TFT VGA Display Operator Interface (indoor),
USB Host, Isolated Comms
10.4" TFT VGA Display Operator Interface (indoor),
Dual Ethernet, USB Host, Isolated Comms
10.4" TFT SVGA Display Operator Interface (indoor),
USB Host, Isolated Comms
10.4" TFT SVGA Display Operator Interface (indoor),
Dual Ethernet, USB Host, Isolated Comms
10.4" TFT VGA Display Operator Interface (indoor or
outdoor), Glossy Finish, USB Host, Isolated Comms
10.4" TFT VGA Display Operator Interface (indoor or
outdoor), Glossy Finish, Dual Ethernet, USB Host,
Isolated Comms
CompactFlash Card
RS 232/485 Optional Communication Card
CANopen Optional Communication Card
DeviceNet Optional Communication Card
GSM/GPRS Modem Option Card
Crimson
RS-232 Programming Cable
USB Cable
Communications Cables
DIN Rail Mountable Adapter Products
Replacement Battery
G310C Backlight Replacement
Protective Films
®
SOCKET TO INCREASE MEMORY CAPACITY
2
ND
ETHERNET PORT OPTIONAL)
DESCRIPTION
6
5
®
1
SOFTWARE (VERSION 2.0 OR
7
3
4
Bulletin No. G310CRS2-A
Drawing No. LP0809
Released 04/10
PART NUMBER
CBLPROG0
G3GSM000
G3PBDP00
CBLUSB00
G3BR10C1
G3RS0000
G3CN0000
G3DN0000
G310C210
G310C230
G310R210
G310R230
G310S210
G310S230
BNL20000
G3FILM10
G3CFxxxx
CBLxxxxx
DRxxxxxx
SFCRM

Related parts for G310R210

G310R210 Summary of contents

Page 1

... Crimson RS-232 Programming Cable USB Cable 1 Communications Cables 4 DIN Rail Mountable Adapter Products 5 Replacement Battery 7 G310C Backlight Replacement Protective Films PART NUMBER G310C210 G310C230 G310R210 G310R230 G310S210 G310S230 G3CFxxxx G3RS0000 G3CN0000 G3DN0000 G3GSM000 G3PBDP00 SFCRM CBLPROG0 CBLUSB00 CBLxxxxx DRxxxxxx BNL20000 G3BR10C1 ...

Page 2

S PECIFICATIONS 1. POWER REQUIREMENTS: +24 VDC ±20 maximum. Must use NEC Class 2 or Limited Power Source (LPS) rated power supply. Power connection via removable three position terminal block. Note: 1. The G310’s circuit common is ...

Page 3

I NSTALLING AND MOUNTING INSTRUCTIONS This operator interface is designed for through-panel mounting. A panel cut- out diagram and a template are provided. Care should be taken to remove any loose material from the mounting cut-out to prevent that material ...

Page 4

... In order to access data from the CompactFlash card via the USB device port, a driver must be installed on your computer. This driver is installed with Crimson and is located in the folder C:\Program Files\Red Lion Controls\ Crimson 2.0\Device\ after Crimson is installed. This may have already been accomplished if your G310 was configured using the USB port. ...

Page 5

Examples of RS232 communications could involve another Red Lion product or a PC. By using a cable with RJ12 ends on it, and a twist in the cable, RS232 communications with another G3 product or the Modular Controller can be ...

Page 6

... The LED backlight is not field replaceable. Unit must be returned to Red Lion Controls for repair. CCFL Backlight Backlight is not field replaceable for hazardous location applications. Unit must be returned to Red Lion Controls for repair. The backlight assembly is field replaceable in non-hazardous locations only. Refer to the instructions included in the appropriate backlight replacement kit ...

Page 7

BATTERY & TIME KEEPING WARNING - EXPLOSION HAZARD - THE AREA MUST BE KNOWN TO BE NON-HAZARDOUS BEFORE SERVICING/ REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I/O WIRING AND BATTERY. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT ...

Page 8

... Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P ...

Related keywords