430251400 Molex Inc, 430251400 Datasheet - Page 2

CONN RECEPT 14POS 3MM DUAL ROW

430251400

Manufacturer Part Number
430251400
Description
CONN RECEPT 14POS 3MM DUAL ROW
Manufacturer
Molex Inc
Series
Micro-Fit 3.0™ 43025r
Datasheets

Specifications of 430251400

Connector Type
Receptacle
Contact Type
Female Socket
Number Of Positions
14
Pitch
0.118" (3.00mm)
Number Of Rows
2
Row Spacing
0.118" (3.00mm)
Mounting Type
Free Hanging (In-Line)
Contact Termination
Crimp
Fastening Type
Latch Lock
Color
Black
Note
Contacts Not Provided
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Other names
043025-1400
043025-1400-C
0430251400-C
43025-1400
43025-1400-C
43025-1400-P
430251400
430251400-C
WM2489

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
430251400
Manufacturer:
MOLEX
Quantity:
60 000
Part Number:
430251400
Manufacturer:
Molex
Quantity:
20 000
Part Number:
430251400
Manufacturer:
Molex, LLC
Quantity:
12 570
Part Number:
430251400
Manufacturer:
MOLEX
Quantity:
35 000
Part Number:
430251400
Manufacturer:
MOLEX
Quantity:
20 000
REVISION:
DOCUMENT NUMBER:
5.0 TESTING PROCEDURES
A
5.1 TERMINAL RETENTION FORCE
5.2 THUMB LATCH TO RAMP YIELD STRENGTH
5.3 THUMB LATCH DURABILITY/CYCLING
TS-43045-003
Microfit 43030 and 43031 terminals were crimped to 20 awg wires and inserted into receptacle
and plug housings, respectively. All circuits were populated. An axial pullout force was applied to
each terminal by pulling on the wire at a rate of 1.0 inch per minute. The maximum force to
dislodge each terminal from the housing was recorded.
Receptacles were mated to header housings to fully engage latches. Header housings were
secured to the base table and the receptacle housings were secured within a grip fixture attached
to the load cell of a motorized force testing device. The crosshead of the device was then moved
in the direction of unmating at a rate of 1.0 inch per minute until the latching geometry of either
the receptacle or the header housing yielded. The maximum force to yield the latch was
recorded.
The thumb latch on the receptacle was first deflected to its extreme until it contacted the body of
the housing (wire insertion side). It was then deflected to its opposite extreme until it contacted
the towers of the housing (mating side). This defined one cycle of the latch. Increments of 5
cycles were repeated on the latch. After each 5 cycle increment the receptacle was mated to a
plug and proper latch engagement was confirmed. Testing was terminated after 50 cycles since
no latch integrity failures were observed and this surpassed the 30 mating cycle rating for these
products by 67%.
ECR/ECN INFORMATION:
EC No:
DATE:
08/12/10
TEST SUMMARY
TITLE:
CREATED / REVISED BY:
SSOUSEK
MICRO-FIT (3.0) CONNECTOR SERIES
NYLON 6 RECEPTACLES AND PLUGS
TEST SUMMARY
CHECKED BY:
JBELL
TEMPLATE FILENAME: TEST_SUMMARY[SIZE_A](V.1).DOC
APPROVED BY:
FSMITH
SHEET No.
2
of
3