ACSL-6210-06R Avago Technologies US Inc., ACSL-6210-06R Datasheet - Page 12

no-image

ACSL-6210-06R

Manufacturer Part Number
ACSL-6210-06R
Description
Bi-Dir Digital Optocoupler
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACSL-6210-06R

Voltage - Isolation
2500Vrms
Number Of Channels
2, Bi-Directional
Current - Output / Channel
50mA
Data Rate
15MBd
Propagation Delay High - Low @ If
44ns @ 8mA
Current - Dc Forward (if)
15mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Package Characteristics
All specifications are at T
Parameter
Input-Output Momentary
Withstand Voltage
Input-Output Insulation
Input-Output Resistance
Input-Output Capacitance
Input-Input Insulation
Leakage Current
Input-Input Resistance
Input-Input Capacitance
Notes:
9. V
10. Measured between each input pair shorted together and all output connections for that channel shorted together.
11. In accordance to UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 3000 Vrms for 1 sec (leakage detection
12. Measured between inputs with the LED anode and cathode shorted together.
Electrostatic Discharge Sensitivity
This product has been tested for electrostatic sensitivity
to the limits stated in the specifications. However, Avago
recommends that all integrated circuits be handled with
appropriate care to avoid damage. Damage caused by
inappropriate handling or storage could range from per-
formance degradation to complete failure.
12
refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), the equipment level safety specification or Avago Applica-
tion Note 1074 entitled “Optocoupler Input-Output Endurance Voltage. ”
current limit, I
60747-5-2 Insulation Characteristics Table, if applicable.
ISO
is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For continuous voltage rating,
I-O
[12]
≤ 5 μA). This test is performed before the 100% production test for partial discharge (Method b) shown in the IEC/EN/DIN EN
[9]
[12]
[10] [11]
A
[12]
[10]
=+25°C.
[10]
SO8
SO16
SO8
SO16
SO8
SO16
SO8
SO16
SO8
SO16
SO8
SO16
SO8
SO16
Symbol
V
V
I
I
R
R
C
C
I
I
R
R
C
C
I-O
I-O
I-I
I-I
I-O
I-O
I-I
I-I
ISO
ISO
I-O
I-O
I-I
I-I
Min.
2500
2500
10
10
9
9
Typ.
10
10
0.7
0.7
0.005
0.005
10
10
0.1
0.12
11
11
11
11
Max.
5
5
Units
V
μA
Ω
pF
μA
Ω
pF
RMS
Test Conditions
RH ≤ 50%, t = 1 min
RH≤50%, t = 1 min
45% RH, t=5 sec, V
45% RH, t=5 sec, V
V
V
f = 1 MHz
f = 1 MHz
RH ≤ 45%, t=5 sec, V
RH≤45%, t=5 sec, V
RH≤45%, t= 5 sec, V
RH≤45%, t=5 sec, V
f = 1 MHz
f = 1 MHz
I-O
I-O
= 500V DC
= 500V DC
I-O
I-O
I-I
I-I
I-I
I-I
= 3kV DC
=500V
=3kV DC
=500V
=500V
=500V