ACPL-P456-020E Avago Technologies US Inc., ACPL-P456-020E Datasheet - Page 4

no-image

ACPL-P456-020E

Manufacturer Part Number
ACPL-P456-020E
Description
Optocoupler(1MBd),UL+LF
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-P456-020E

Voltage - Isolation
5000Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
15mA
Propagation Delay High - Low @ If
200ns @ 10mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Package / Case
SO-6
Number Of Elements
1
Forward Voltage
1.8V
Forward Current
25mA
Output Current
15mA
Isolation Voltage
5000Vrms
Operating Temp Range
-40C to 100C
Current Transfer Ratio
90%
Power Dissipation
145mW
Propagation Delay Time
550ns
Pin Count
6
Mounting
Surface Mount
Reverse Breakdown Voltage
5V
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-P456/W456 Option 060)
*
Table 2. Insulation and Safety Related Specifications
4
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values – maximum values
allowed in the event of a failure.
Insulation Resistance at T
Parameter
Minimum External Air Gap
(External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
IORM
IORM
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Case Temperature
Input Current
Output Power
x 1.875=V
x 1.5=V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
ini
S
, V
= 60 sec)
IO
= 500 V
Symbol
L(101)
L(102)
CTI
m
=10 sec,
ACPL-P456
m
>175
0.08
NA
7.0
8.0
IIIa
=1 sec,
ACPL-W456
>175
0.08
8.0
8.0
NA
IIIa
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
S, OUTPUT
S
IORM
PR
PR
IOTM
Units
mm
mm
mm
mm
V
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
ACPL-W456
I – IV
I – IV
I – III
I – III
I – II
55/100/21
2
1140
2138
1824
8000
175
230
600
>10
9
ACPL-P456
I – IV
I – IV
I – III
I – III
2
891
1671
1425
6000
175
230
600
>10
55/100/21
9
Unit
V
V
V
V
°C
mA
mW
:
peak
peak
peak
peak