Led Color
White
Supply Voltage
12V
Mounting Hole Dia
16mm
Forward Current If
9mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• Turn off the power to A series control units before starting
• To avoid burning your hand, use the lamp holder tool when
36
Replacement of Lens and Marking Plate
• Removal
Remove the lens assembly (color lens, marking plate, lens holder,
and spring) by holding the color lens recesses with the Lens
Removal Tool (MT-101) and pulling it out. Remove the marking plate
by disengaging the latches between the color lens and lens holder.
The marking plate must be engraved on the front side as shown
below.
Note: Make sure that the spring is inserted in the correct
• Installation
Place the marking plate on the lens holder in the correct direction,
and press the color lens onto the lens holder to engage the latches.
Put the spring on the lens holder and insert the lens holder into the
housing in the correct direction.
• Installing Non-illuminated Button
Non-illuminated pushbuttons contain a marking plate like illumi-
nated units. Be sure to install the marking plate when replacing the
button.
Replacing the LED Lamp
• Removal
Use the lamp holder tool (OR-66) to remove lamps. Do not use
pliers.
• Installation
Use the lamp holder tool (OR-66) to install lamps. Note the correct
side of the tool for removal or installation.
Panel Mounting
When mounting the control units into a panel, use the optional
locking ring wrench (MT-003) to tighten the locking ring. Do not use
pliers. Tightening torque must not exceed 0.29 N·m. Excessive
tightening will damage the locking ring.
ø10
installation, removal, wiring, maintenance, and inspection of the
control units. Failure to turn power off may cause electrical shocks
or fire hazard.
replacing lamps.
Safety Precautions
Operating Instructions
direction. The base of spring must fit the groove in the
holder.
Color lens
A1
For removing lamps
Engraving
Area
Series
OR-66 (ø8, ø10, ø12 series)
Lamp Holder Tool
Marking
Plate
Latches
Miniature Control Units
Lens
Holder
For installing lamps
Spring
Retaining
Groove
Spring
• For wiring, use wires of a proper gauge to meet the voltage and
Wiring
Solder the terminal at 350°C within 3 seconds using a 60W
soldering iron. Sn-Ag-Cu type is recommended when using lead-
free solder. When soldering, do not touch the control unit with the
soldering iron. Also ensure that no tensile force is applied to the
terminal. Do not bend the terminal or apply excessive force to the
terminal.
Use non-corrosive rosin flux.
Installing the Socket
Install the socket on the control unit with the TOP markings on the
control unit and the socket placed in the same direction.
Operating Voltage of LED Lamps
The operating voltage is measured at complete DC. When using a
pulsating voltage such as a full-wave rectification voltage, keep
peak currents within the forward current If. Peak currents exceeding
the If may shorten the LED lamp life.
Other Notes
• Close Proximity Mounting
When mounting pilot lights or illuminated pushbuttons collectively or
lighting them continuously, heat may cause the ambient
temperature to rise above the rated operating temperature. When
the mounting panel is not made of metal or when the control units
are mounted in an enclosed panel, provide for ventilation or lower
the operating voltage.
• Replacement of Buttons (Illuminated/Non-illuminated)
Do not replace buttons of maintained action units while the button is
in the locked position. Replacing the button in the locked position
may damage the internal mechanism. Be sure to release the button
before replacing.
• Operating and Storage Environment
1. Make sure that the operating/storage temperature and humidity
2. Do not use enclosed type units in an environment subject to oil,
• Microswitch Contacts
Do not connect NO and NC contacts of the microswitch to different
voltages or different power sources to prevent a dead short-circuit.
current requirements. Failure to tighten terminal screws may
cause overheating and create a fire hazard.
are within the ratings.
water or dust accumulation.
(06/11/10)