TUS16NL ETERNA, TUS16NL Datasheet - Page 2

FLUORESCENT FITTING, T4, 16W, LOW ENGY

TUS16NL

Manufacturer Part Number
TUS16NL
Description
FLUORESCENT FITTING, T4, 16W, LOW ENGY
Manufacturer
ETERNA
Datasheet

Specifications of TUS16NL

Supply Voltage
230V
Base Type
T4
Power Rating
16W
Length
520mm
Colour Temperature Typ
3400K
Svhc
No SVHC (15-Dec-2010)
Colour
White
External Length / Height
520mm
External Width
19mm
Lamp Base Type
T4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Read this first:
>
>
>
>
>
>
>
>
>
>
>
>
Safety markings:
Warning:
The leads supplied with your light fitting and the sockets incorporated in your fitting are designed to give protection
against any possible electrical hazard. The mains lead is terminated in a socket marked NLS and this lead should be
used to supply mains to your fitting or chain of fittings. Under no circumstances should you attempt to adapt the link
lead to supply power to the opposite end of your fitting as this will leave live pins exposed at the mains input end of
the fitting. Altering or adapting any of the leads, other than shortening the mains supply lead, will invalidate your
guarantee and could present a severe electrical shock hazard.
This light fitting must be installed in accordance
with the Building Regulations. These may be
obtained from HMSO or viewed and downloaded from
www.communities.gov.uk following the link for Building
Regulations.
If in any doubt, consult a qualified electrician.
Switch off the mains before commencing installation
and remove the appropriate circuit fuse.
Do not connect to a circuit which also has inductive
loads connected as spikes generated switching
inductive loads may damage electronic components
within your electronic fitting.
Suitable for indoor use only.
This product is only suitable for use in living areas ( not
for areas constantly subject to moisture ).
This product is suitable for installation on surfaces with
normal flammability ( indicated by the "F" in a triangle )
e.g. wood, plasterboard, masonry. It is not suitable for
use on highly flammable surfaces ( e.g. polystyrene,
textiles ).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface such
as pipes or cables.
The chosen location of your new fitting should allow for
the product to be securely mounted and safely
connected to the mains supply ( lighting circuit ).
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive (e.g.
metallic surfaces).
If the location of your new fitting requires the provision
of a new electrical supply, the supply must conform
with the requirements of the Building Regulations.
This product is designed for permanent connection to
fixed wiring: this should be either a suitable lighting
>
>
>
>
Installation:
1)
2)
3)
4)
5)
6)
7)
circuit ( protected with a 5 or 6 Amp MCB or fuse ) or a
fused spur ( with a 3 Amp fuse ) via a fused connection
unit. We recommend that the supply incorporates a
switch for ease of operation.
Make connections to the electrical supply in
accordance with the following code:
This fitting is double insulated, do not connect any part
to earth.
A maximum of six fittings may be linked together in
one chain.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation there
are electrical tests that should be carried out: these
tests are specified in the Wiring Regulations ( BS7671 )
referred to in the Building Regulations. If in doubt,
consult a qualified electrician.
When positioning the fitting, make sure there is a gap
of at least 10mm between the lamp and any adjacent
surface. See figure 1, opposite.
Select the type of brackets you need to use and mark
off the fixing points. If fixing to a shelf or under a
cupboard, check the screw size required and screw
into place. See figures 2 and 3, opposite.
If fixing directly to the wall, drill holes using a N°5 /
8mm drill bit to a depth of 30mm and insert wall plugs.
Secure the selected brackets in place using the screws
supplied.
Attach the fitting to the clips.
Connect the mains lead or link lead to the socket on
your fitting.
Restore the power supply and switch on.
Live - Brown or Red
Neutral - Blue or Black
How to link multiple fittings together.
Option 1. The light fittings can be butted together to form a line of up to a maximum of 6 fittings. Simply remove the
connector caps and push the fittings together.
Use the mains lead cable to connect the first fitting and the mains via a
spur or junction box.
Option 2. Connect link leads between each fitting and once all lights have
been connected, connect the mains lead to the mains via a spur or junction
box.
Option 3. For more than one unlinked
light, use a socket block ( available
as an optional extra ) and simply
plug the 13A plug into your
nearest socket outlet.
End view
1
End view
10mm gap
Fixing clip
3
10mm gap
Fixing clip
End view
End view
Fixing clips