DS9840 OSRAM, DS9840 Datasheet - Page 67

LAMP, DULUX, S, COOL, 9W

DS9840

Manufacturer Part Number
DS9840
Description
LAMP, DULUX, S, COOL, 9W
Manufacturer
OSRAM
Datasheet

Specifications of DS9840

Supply Voltage
60V
Base Type
2 Pin
Power Rating
9W
Luminous Flux
600lm
Length
167mm
Colour Temperature Typ
4000K
Svhc
No SVHC (15-Dec-2010)
External Depth
19.5mm
External Diameter
19.5mm
External
RoHS Compliant
Lamp Base Type
2 Pin
Rohs Compliant
Yes
Average Bulb Life
8000h
Bulb Diameter
19.5mm
Economical long-life light sources with plug-in bases.
Compact Fluorescent Lamps OSRAM DULUX
Technical Guide
66
7.3
7.2
7.4
7.5
Operating position
Constant
photometric
values
Electrical
measurements
Temperature
measurement
Free-burning OSRAM DULUX
although according to the IEC the reference burning position for OSRAM DULUX
and OSRAM DULUX
the measurements are easier to take and the results are more reliable since the mer-
cury remains at the cold spot at the bottom even when the lamp is moved.
With lamps in the horizontal burning position, the mercury shifts as soon as the lamp is
moved, which destabilises the lamp.
The difference in luminous flux between the base-up and horizontal operating positi-
ons at constant lamp output for OSRAM DULUX
than 1 to 2 %. Deviations of 10 to 20 % can be expected for OSRAM DULUX
and T/E IN lamps between base up and horizontal operating position.
Burnt-in and stabilised OSRAM DULUX
at constant ambient temperature and in an unchanged operating position. Fluctuations
are less than 1 % of the upper range value.
All the cables, control gear and instruments must be arranged, and if necessary shiel-
ded, so that there is no chance of interference from external fields. Use instruments
which will supply the level of accuracy required in the measured values.
Recommendations:
Instruments:
Lamp supply:
The luminous flux and hence the luminous efficacy of OSRAM DULUX
depends on the temperature. To achieve optimum operating conditions for the lamp in
the luminaire, it is therefore essential to know either the ambient temperature in the
vicinity of the lamp or the cold spot temperature directly on the lamp.
®
®
F lamps is horizontal. The base-up position is chosen because
Rms instruments (true RMS)
Accuracy:
Area of application
Frequency:
Crest factor:
Supply voltage:
Stability:
Total harmonic distortion:
Suitable supply:
The apparent power of the supply unit should be five times
the rated system power.
®
lamps are generally measured in the base-up position,
®
lamps provide reproducible photometric data
®
S, S/E, D, D/E, T, T/E is no more
7. Measuring OSRAM DULUX
±0,2% of the measuring range
0-500 Hz (CCG) scanning rate
0-400 kHz (ECG) scanning rate
> 2 (CCG)
> 3 (ECG)
Depending on the lamp and
control gear (CCG, ECG or
reference device)
± 0,2% during the
measurement
< 3%
- Noise-free mains
- Electronically regulated
- Rotary measuring generators
- Electronic generators
stabilisers
compact fluorescent lamps
®
lamps
®
T IN
®
L
®