FL124B ETERNA, FL124B Datasheet - Page 2

no-image

FL124B

Manufacturer Part Number
FL124B
Description
FLOODLIGHT, 24W, LOW ENERGY
Manufacturer
ETERNA
Datasheet

Specifications of FL124B

Light Source
Fluorescent
Length
135mm
Width
210mm
Depth
100mm
Ip/nema Rating
IP44
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
BS EN 60598
Colour
Black
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
General Information, Safety and Installation Instructions
Read this first
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not, contact
the outlet where you bought this product.
This product contains glass, care must be taken when
assembling, fitting or handling to prevent personal
injury or damage to the product.
This light fitting must be installed by a competent
person in accordance with the Building Regulations
making reference to the current edition of the IEE
Wiring Regulations (BS7671). The Building Regulations
may be obtained from HMSO or viewed and
downloaded from www.communities.gov.uk following
the link for Building Regulations.
As the buyer, installer and/or user of this product it is
your own responsibility to ensure that this fitting is fit
for the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage or
premature failure resulting from inappropriate use.
If in any doubt, consult a qualified electrician.
The lamps (bulbs/tubes) supplied with this fitting are
consumable parts and therefore may be outside of any
warranty offered.
Switch off the mains before commencing installation
and remove the appropriate circuit fuse.
When working at heights, please use a suitable
platform.
Disconnect the fitting from the electrical supply before
flash or high voltage testing.
Suitable for indoor and outdoor use.
This product is suitable for installation on surfaces
with normal flammability e.g. wood, plasterboard, and
masonry. It is not suitable for use on highly flammable
surfaces (e.g. polystyrene, textiles).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new fitting should allow
for the product to be securely mounted and safely
connected to the mains supply (lighting circuit).
When choosing the location for your new fitting,
ensure that the fixings will be anchored in a solid
surface e.g. concrete, brick or a joist—do not fix directly
onto panelling, cladding, plasterboard etc.
If the location of your new fitting requires the provision
of a new electrical supply, the supply must conform
with the requirements of the Building Regulations
making reference to the current edition of the IEE
Wiring Regulations (BS7671).
This product is designed for permanent connection to
fixed wiring: this should be either a suitable lighting
circuit (protected with a 5 or 6 Amp MCB or fuse) or a
fused spur (with a 3 Amp fuse) via a fused connection
unit.
We recommend that the supply incorporates a switch
for ease of operation.
Make connections to the electrical supply in
accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
Earth - Green and Yellow
When making connections, ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened onto
the bared conductors and not onto any insulation.
This product must be connected to Earth.
IMPORTANT— Always switch off at the mains before
changing the lamp.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation there
are electrical tests that should be carried out: these
tests are specified in the Wiring Regulations (BS7671)
referred to in the Building Regulations. If in doubt,
consult a qualified electrician.
Installation
1. Choose the location for your new floodlight giving
2. Using the fixing strap as a template, mark the
3. Prepare your mounting surface as appropriate for
4. Secure the fitting in place.
5. Loosen the bolts at each end of the fixing strap and
6. Tighten the bolts to lock your floodlight in position.
7. Make the connections to your mains supply as
8. Using a cross-headed screwdriver, undo the screws
9. Fit the fluorescent lamp.
consideration to all of the conditions listed above.
position for the fixing holes on your mounting
surface.
your chosen fixings (not supplied). Use a spirit level
to ensure the fitting will be level.
adjust the angle of your floodlight to give the
desired spread of light.
described in the “Read this first” section.
that secure the diffuser and allow to hang down.
Installation Instructions and Care
10. Replace the diffuser and tighten the screws
11. Press the trim back onto the front of the fitting
12. Restore the power and switch on.
Specification
Voltage:
Weatherproof: IP44
Class I Protection: Class I / Earthed
Safety Markings:
Cleaning
Disconnect the power and clean the exterior only of
this fitting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
Lamp Replacement
1. Switch off the electricity at the mains.
2. Using a cross-headed screwdriver, undo the screws
3. Remove the lamp.
4. Insert new lamp.
5. Replace the diffuser and secure in position making
6. Restore the power and switch on.
Replacement Lamp Type
Wattage:
Type:
that secure the diffuser and allow to hang down.
sure that the gasket is correctly positioned and
compressed.
making sure that the waterproof gasket is correctly
positioned and compressed.
making sure the slots used for removal are at the
bottom.
220-240 V 50 Hz
24W
24W ES Helical CFLi
IP44