6D301 4D SYSTEMS, 6D301 Datasheet - Page 10

OLED DISPLAY, 128x128 PIXELS, 27mmx27mm

6D301

Manufacturer Part Number
6D301
Description
OLED DISPLAY, 128x128 PIXELS, 27mmx27mm
Manufacturer
4D SYSTEMS
Datasheet

Specifications of 6D301

Screen Size
38.1mm
Resolution
128 X 128
Viewing Area (h X W)
27mm X 27mm
Interface Type
Serial, USB
Voltage Rating
5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Serial Timing:
Each serial command is made up of a sequence of data bytes. Some
commands are single byte and others are multiple bytes. When a
command is sent, the module will reply back with a single acknowledge
byte called the
command was understood and the operation is completed. It will take the
module anywhere between 1 to several milliseconds to reply back with an
ACK, depending on the command and the operation it has to perform.
If the module receives a command that it does not understand it will
reply back with a negative acknowledge called the
For example, if a command has 5 bytes but only 4 bytes are sent, the
command will not be executed and the
another byte is sent before trying to execute the command. There is no
timeout when incomplete commands are sent. The module will reply back
with a
make sure the command bytes are sent in the correct sequence.
Power-Up Reset:
When the
the Graphics RAM and the internal Display registers. Allow up to 1 second
before attempting to communicate with the
sequence of events should be as follows:
internal initialisations to complete. Do not attempt to communicate
with the module during this period. The module may send garbage
on its Tx Data line during this period; the host should disregard any
data.
transmit (TX) line pulled HIGH. If the host TX (module Rx) is LOW
after the 100ms period, it may misinterpret this as the START bit
and lock onto some unknown Baud Rate.
command so the module can lock onto the host’s serial baud rate.
This is called “Auto Bauding”. The module will respond with an
‘ACK’ (06hex). See previous section.
the host.
Allow up to 1000ms after power-up for voltages to settle and
Within 100ms of powering up, the host should make sure it has its
The host must transmit the ASCII ‘U’ (capital U, 55hex) as the first
The module is now ready to accept screen function commands from
NAK
µOLED-128-G1
for each invalid command it receives. For correct operation
ACK
(06hex). This tells the host controller that the
www.4dsystems.com.au
µ
OL
comes out of a power up reset, it initialises
E
D-128-
G1
µOLED-128-G1
module.
NAK
(15hex).
The power up
will wait until
10