H5BR-B-AC24/DC12-24 Omron, H5BR-B-AC24/DC12-24 Datasheet - Page 4

no-image

H5BR-B-AC24/DC12-24

Manufacturer Part Number
H5BR-B-AC24/DC12-24
Description
TIMER DIGITAL LCD
Manufacturer
Omron
Series
H5BRr
Datasheet

Specifications of H5BR-B-AC24/DC12-24

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5BRBAC24/DC1224
H5BRBAC24DC1224
H5BR
Output mode A-3: Power ON delay 2 (Timer does not reset when power comes on.)
Output mode B: Repeat cycle 1 (Timer resets when power comes on.)
Output mode A-2: Power ON delay 1 (Timer resets when power comes on.)
Timing
diagram
Timing
diagram
Timing
diagram
Timing
diagram
Control output
Control output
Control output
Control output
UP
UP
Start signal
DOWN
UP
DOWN
Start signal
DOWN
UP
DOWN
Start signal
Start signal
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Power
Power
Power
Power
Reset
Reset
Reset
Reset
Gate
Gate
Gate
Gate
0
0
0
0
0
0
0
0
Sustained output
One-shot
One-shot output can be set from 0.1 s to 99.9 s.
a = one-shot time before power interruption
t-a = remaining one-shot time after power interruption
4
Timing begins when power is applied.
Start signals act as a gate input,
causing the present value to hold. The
control output will be energized when
the present value equals the preset
time. The output will be sustained until
a reset signal is applied, until power is
interrupted, or for a programmable
one-shot time period.
Timing begins when power is applied.
Start signals act as a gate input, causing
the present value to hold. The control
output will be energized when the
present value equals the preset time.
The output will be sustained until a reset
signal is applied or for a programmable
one-shot time period. If power to the unit
is interrupted, the control output will be
de-energized. The output will re-
energize once power is restored.
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
output relay will be OFF for the preset
time, then ON for the preset time. The
cycle will be repeated until a reset input
is applied or power is interrupted.
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
control output will be OFF for the first
cycle. In subsequent cycles the output
will be ON for the programmable one-
shot time period, then OFF for the
remainder of the preset time. The cycle
will be repeated until a reset input is
applied or power is interrupted.
H5BR

Related parts for H5BR-B-AC24/DC12-24