H3CR-A8E AC/DC24-48 Omron, H3CR-A8E AC/DC24-48 Datasheet - Page 18

SOLID STATE TIMER-ANALOG SET

H3CR-A8E AC/DC24-48

Manufacturer Part Number
H3CR-A8E AC/DC24-48
Description
SOLID STATE TIMER-ANALOG SET
Manufacturer
Omron
Series
H3CR-Ar
Type
Solid State Multi-Functional Timerr

Specifications of H3CR-A8E AC/DC24-48

Rohs Compliant
YES
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 48VAC, 12 ~ 48VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 sec to 300 hrs
Supply Voltage
24 V to 48 V
Accuracy
+/- 0.2 %
Operating Temperature Range
- 10 C to + 55 C
Product
Analog Timer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A8E-AC/DC24-48
H3CRA8EACDC2448
Z2381
2. Signal Start/Signal Reset (in B Mode)
If there is an abnormal signal, flashing starts. When the abnormal
condition is restored, a reset signal stops the display flashing.
C Mode: Signal ON/OFF-delay
The Signal ON-/OFF-delay operation (C mode) is useful for the
control of distribution of products on a production line into boxes by
the specified number or time.
1. Power-ON Start/Instantaneous Operation/
A set of these functions is useful for the operation of a machine for a
specified period when power is ON.
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Time-limit Reset
Power (2 and 10)
Power (2 and 10)
Power indicator
Reset (2 and 7)
Power indicator
Start (2 and 6)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Externally short-circuited
Start signal
Reset signal
Lit
(Power continuously supplied)
Flashing
t
Power
supply
Lit
Power
supply
Flashing
Flashing
t
t
Lit
t
Lit
2. Signal-ON-OFF Start/Instantaneous
D Mode: Signal OFF-delay
Signal OFF-delay operation (D mode) can be effectively used to keep
a load operating for a certain period. For example, this function
enables the cooling fan for a lamp or heater to operate for a certain
period after the lamp or heater is switched OFF.
1. Power-ON Start/Instantaneous Operation/
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Operation/Time-limit Reset
Time-limit Reset
Power (2 and 10)
Power (2 and 10)
Power indicator
Power indicator
Start (2 and 6)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Start signal (NC to NO)
Start signal
(The operation starts with the signal ON or OFF)
(Power continuously supplied)
Lit
Power
supply
Power
supply
Flashing
H3CR-A
Lit
18