H5CN-YCN-AC100-240 Omron, H5CN-YCN-AC100-240 Datasheet - Page 7

TIMER DIGITAL LED

H5CN-YCN-AC100-240

Manufacturer Part Number
H5CN-YCN-AC100-240
Description
TIMER DIGITAL LED
Manufacturer
Omron
Datasheet

Specifications of H5CN-YCN-AC100-240

Rohs Compliant
YES
Supply Voltage Range
100VAC To 240VAC
Power Consumption
2.5W
Reset Time
20ms
Time Range
1s To 99min 59s
Installation
■ Connections
1. Battery Connection (H5CN-X@NM
Only)
Model with Backup
Power for Memory
Protection
Connect the Y92S-20 Backup Bat-
tery between terminals A and D,
making sure the polarities are cor-
rect.
2. Power Supply Connection
Model without Backup Power for Memory
Protection
Connect the timer so that the required supply voltage can be applied
across terminals B and G. (Make sure that the polarity of the DC
power supply is correct.)
Model with Backup Power for Memory
Protection (H5CN-X@NM)
Connect the timer so that the required supply voltage can be applied
across terminals B and J.
3. Connection of Load Circuit (Control
Output)
Model without Backup Power for Memory
Protection
Contact Output Type
Internal Circuit of Control Output
Contacts
Terminals E, F, and H are for con-
trol output contacts.
AC Power Supply
100 to 240 VAC
External
battery
100 to 240 VAC
External
battery 3 V
DC Power Supply
12 to 48 VDC
Connecting of Load Circuit
Load 1 connected in series with NO contact (between terminals F
and H) is normally open, and the load circuit voltage will be applied
after the lapse of the set time. The load circuit voltage is normally
applied to load 2 connected in series with NC contact (between ter-
minals E and H), which will be open after the lapse of the set time.
Note: The maximum load current is 3 A (resistive load).
Solid-state Output Type
Internal Circuit of Control Output
Terminals F and H are an open collector output. A diode is inter-
nally connected between terminals E and F to absorb counterelec-
tromotive force that occurs when an inductive load is connected.
Connection of Load Circuit
Voltage is applied to the load after the set time has lapsed.
Note: The maximum load current is 100 mA.
Model with Backup Power for Memory
Protection (H5CN-X@NM)
Contact Output Type
Internal Circuit of Control Output Contacts
Terminal H, I, and K are for control output contacts.
External
battery
Load 2
Load 1
Load
Load circuit voltage
(250 VAC, 30 VDC max.)
Load voltage
(30 VDC max.)
H5CN
7