IRAUDAMP8 International Rectifier, IRAUDAMP8 Datasheet - Page 22

no-image

IRAUDAMP8

Manufacturer Part Number
IRAUDAMP8
Description
BOX / 9999V 999.000A OTHER
Manufacturer
International Rectifier
Datasheet

Specifications of IRAUDAMP8

Lead Free Status / Rohs Status
Not Compliant
Over-Current Protection (OCP)
Low-Side Current Sensing
The low-side current sensing feature protects the low side DirectFET from an overload condition
from negative load current by measuring drain-to-source voltage across R
during its on state.
DS(ON)
OCP shuts down the switching operation if the drain-to-source voltage exceeds a preset trip level.
The voltage setting on the OCSET pin programs the threshold for low-side over-current sensing.
When the VS voltage becomes higher than the OCSET voltage during low-side conduction, the
IRS2093 turns the outputs off and pulls CSD down to -VSS.
High-Side Current Sensing
The high-side current sensing protects the high side DirectFET from an overload condition from
positive load current by measuring drain-to-source voltage across R
during its on state. OCP
DS(ON)
shuts down the switching operation if the drain-to-source voltage exceeds a preset trip level.
High-side over-current sensing monitors drain-to-source voltage of the high-side DirectFET during
the on state through the CSH and VS pins. The CSH pin detects the drain voltage with reference
to the VS pin, which is the source of the high-side DirectFET. In contrast to the low-side current
sensing, the threshold of the CSH pin to trigger OC protection is internally fixed at 1.2V. An
external resistive divider R15, R16 and R17 are used to program a threshold as shown in Fig 18.
An external reverse blocking diode D1 is required to block high voltage feeding into the CSH pin
during low-side conduction. By subtracting a forward voltage drop of 0.6V at D1, the minimum
threshold which can be set for the high-side is 0.6V across the drain-to-source.
Over-Voltage Protection (OVP)
OVP is provided externally to the IRS2093. OVP shuts down the amplifier if the bus voltage
between GND and -B exceeds 39V. The threshold is determined by a Zener diode Z3. OVP
protects the board from harmful excessive supply voltages, such as due to bus pumping at very
low frequency-continuous output in stereo mode.
Under-Voltage Protection (UVP)
UVP is provided externally to the IRS2093. UVP prevents unwanted audible noise output from
unstable PWM operation during power up and down. UVP shuts down the amplifier if the bus
voltage between GND and -B falls below a voltage set by Zener diode Z4.