K3601G Littelfuse Inc, K3601G Datasheet - Page 5

SIDAC, 380V, 1A, DO-15

K3601G

Manufacturer Part Number
K3601G
Description
SIDAC, 380V, 1A, DO-15
Manufacturer
Littelfuse Inc
Datasheet

Specifications of K3601G

Breakover Voltage Range
340V To 380V
Breakover Current Max.
10µA
Peak Forward Current
1A
Thyristor Case
DO-15
No. Of Pins
2
Gate Trigger Current Max, Igt
0.01mA
Peak Surge Current 50/60 Hz, Itsm
20A
Filter Terminals
Axial Leaded
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications are subject to change without notice.
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.
Please refer to http://www.littelfuse.com for current information.
©2008 Littelfuse, Inc.
©2008 Littelfuse, Inc.
Physical Specifications
Terminal Finish
Body Material
Lead Material
Package
DO-15
Design Considerations
Careful selection of the correct device for the application’s
operating parameters and environment will go a long
way toward extending the operating life of the Thyristor.
Overheating and surge currents are the main killers of
SIDACs. Correct mounting, soldering, and forming of the
leads also help protect against component damage.
Dimensions — DO-15 (G Package)
Product Selector
K2201G
K2401G
K2501G
K3601G
Part Number
L
100% Matte Tin Plated
UL recognized epoxy meeting flammability
classification 94V-0
Copper Alloy
385
V
BO
G
Minimum
200V
220V
240V
340V
Switching Voltage Range
Weight / unit (mg)
D
Teccor
Teccor
Multipulse™ SIDACs
L
V
BO
Maximum
230V
250V
280V
380V
®
®
brand Thyristors
brand Thyristors
Revised: August 29, 2008
B
335
335
Blocking Voltage
Dimension
High Temperature
Voltage Blocking
Temperature Cycling
Temperature /
Humidity
High Temp Storage
Low-Temp Storage
Thermal Shock
Autoclave
Resistance to
Solder Heat
Solderability
Repetitive Surge
Life Testing
Reliability/Environmental Tests
200V
270V
180V
190V
V
DRM
D
G
B
L
Test
0.028
0.120
0.235
1.000
Max
Packages
Inches
DO-15
DO-15
DO-15
DO-15
MIL-STD-750: Method 1040, Condition
A Rated V
hours
MIL-STD-750: Method 1051, 100 cycles;
-40°C to 150°C, 15-minute dwell time
EIA/JEDEC: JESD22-A101
1008 hours; 160V - DC: 85°C;
85% relative humidity
MIL-STD-750: Method 1031
150°C, 1008 hours
-40°C, 1008 hours
MIL-STD-750: Method 1056
10 cycles; 0°C to 100°C; 5-minute dwell-
time at each temperature; 10-sec (max)
transfer time between temperature
EIA/JEDEC: JESD22-A102
168 hours (121°C at 2 ATMs) and
100% RH
MIL-STD-750: Method 2031
260°C, 10 seconds
ANSI/J-STD-002: Category 3, Test A
Multi firings per half cycle at 60Hz in
application circuit for 168 hours minimum
0.034
0.140
0.270
Specifications and Conditions
Max
DRM
(VAC-peak), 125°C, 1008
25.400
0.711
3.048
5.969
Min
Millimeters
Kxxx1G Series
0.864
3.556
6.858
Max

Related parts for K3601G