... DC power supplies for control panels, and other general DC power equipment OUTLINE DRAWING & CIRCUIT DIAGRAM 13 14 LABEL MITSUBISHI DIODE MODULES RM20TPM-H MEDIUM POWER GENERAL USE I DC output current ....................... 40A O V Repetitive peak reverse voltage RRM 3 phase bridge Insulated Type 2- 4.5 5-M4 INSULATED TYPE ...
... Test conditions T =150 C, V applied j RRM T = =40A, instantaneous meas Junction to case Case to fin, conductive grease applied Measured with a 500V megohmmeter between main terminal and case MITSUBISHI DIODE MODULES RM20TPM-H MEDIUM POWER GENERAL USE INSULATED TYPE Unit Ratings Unit 40 A 400 4.2 ...
... DC OUTPUT CURRENT (A) ALLOWABLE SURGE (NON-REPETITIVE) 500 400 300 200 100 0 1.4 1.6 1.8 2 – MITSUBISHI DIODE MODULES RM20TPM-H MEDIUM POWER GENERAL USE INSULATED TYPE FORWARD CURRENT 100 CONDUCTION TIME (CYCLES AT 60Hz) MAXIMUM POWER DISSIPATION OUTPUT CURRENT (A) Mar.2002 ...