US3J2PAK Littelfuse Inc, US3J2PAK Datasheet - Page 28

BULK / ACS LPSJ 30A 2 POLE ASSEMBLY KIT

US3J2PAK

Manufacturer Part Number
US3J2PAK
Description
BULK / ACS LPSJ 30A 2 POLE ASSEMBLY KIT
Manufacturer
Littelfuse Inc
Series
POWR-SAFEr
Type
Assembly kit for 2 LFPSJ301.Zr
Datasheet

Specifications of US3J2PAK

Accessory Type
Multipole Kit
Fuse Size / Group
Class J
Mounting Style
DIN Rail
Body Material
Thermoplastic
Number Of Poles
2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Fuse; LPSJ
Lead Free Status / Rohs Status
No
POWR-BLOKS
Distribution/Splicer Blocks and Covers
POWR-BLOKS power distribution blocks offer a safe, convenient way
of splicing cables, providing a fixed junction tap-off point or splitting
primary power into secondary circuits. LX2xxx-DIN series offers integral
DIN-Rail mount and an optional hinged safety cover.
Applications
Typical applications include heating, air conditioning and refrigeration
systems, elevator systems, material handling equipment, control
panels, motor controls, switchgear, and anywhere power needs to be
distributed to more than one load.
Specifications
Voltage Rating:
Amperage:
Material:
© 2005 Littelfuse
POWR-GARD
600V
Based on NEC Table 310.16,
using 75°C copper wire
Phenolic rated at 150°C and Thermoplastic rated at
125°C (LD1400 and LS1300 series only)
Products Catalog
w w w . l i t t e l f u s e . c o m
Blocks and Holders
Connectors
Box lug connectors are designed for use with a single, solid or class
B or C stranded conductor. Use of more than one conductor per
connector opening or use of extra-flexible, fine stranded conductors,
such as welding cable, voids the UL Listing, and may cause overheating.
Manufacturers of cable terminations can furnish crimp-on sleeves for
fine stranded conductors which permit these conductors to be used with
box lugs.
Ampere Ratings
The ampere rating per pole for power distribution blocks is based on
the line ampacity of 75°C insulated conductors per NEC Table 310.16. If
60°C insulated conductors are used, load must not exceed the ampacity
of 60°C conductors. Use of conductors rated in excess of 75°C is
permitted (for example 90°C), however, load must not exceed the
ampacity of 75°C conductors.
Ordering Information
Note: Aluminum blocks can use copper or aluminum wire; copper blocks can
only use copper wire.
Connector:
Flammability Rating:
Approvals:
Distribution Block
Example Part No.
Standard: Highly conductive aluminum, tin plated
Copper: Highly conductive copper, tin plated
94V-0
UL Recognized (File No. E171395)
CSA Certified (File No. LR700111)
Example Part No.
Splicer Block
137