PGR-6200-04-00-MPU Littelfuse Inc, PGR-6200-04-00-MPU Datasheet - Page 2

no-image

PGR-6200-04-00-MPU

Manufacturer Part Number
PGR-6200-04-00-MPU
Description
BULK / MPR WITH TIA-232/ETHERNET - RELAY ONLY
Manufacturer
Littelfuse Inc
Datasheet

Specifications of PGR-6200-04-00-MPU

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
© 2010 Littelfuse
POWR-GARD
Motor Protection – Advanced (PGR 6000 Family)
Ordering Information
Features & Benefits
Simplified Circuit Diagram
NOTE: The PGR-6200 consists of the Motor Protection Relay and the PGA-0CIM Current Input
Module. To order the relay only, add (-MPU) to the part number listed above.
FeAtUReS
Overload
Unbalance (Current)
RTD & PTC Overtemperature
Phase Loss/Phase Reverse
(Current)
Overcurrent/Jam
Undercurrent
RTD Temperature
Starts Per Hour
Differential
Dynamic Thermal Model
Communications
Ground Fault
Reduced Overcurrent Mode
Metering
PGA-0CIM
Analog Output
Data Logging
Conformal Coating
CAtAloG/SySteM NUMBeR
PGR-6200-00-00
PGR-6200-01-00
PGR-6200-02-00
PGR-6200-04-00
ACCeSSoRieS
PGC Family
PGA-0120
PGA-0140
PGK-0SMK
L1
L2
L1
L2
POWR-GARD
PGA-0CIM
(Current Input Module)
POWR-GARD
PGR-6200
(Motor Protection Relay)
A
POWR-GARD
PGR-6300
(Operator Interface)
POWR-GARD
PHASE CT
PHASE CT
POWR-GARD
PGR-6300
(Control Unit)
®
®
PHASE CT
PHASE CT
®
PHASE CT
®
PHASE CT
®
Protection Relay Catalog
1
GF CT
®
Protection Relays, Monitors & Systems
GF CT
2
B
CoMMUNiCAtioN
TIA-232
TIA-232 & RS-485
TIA-232 & DeviceNet™
TIA-232 & Ethernet
ReqUiReMeNt
Optional
Optional
Optional
Optional
50G/N, 51G/N Prevents catastrophic failures and fires
ieee #
50, 51
38, 49
46
49
46
37
66
87
POWR-GARD
PGA-0120
(Temperature Input Module)
M
BeNeFitS
Extends motor life and prevents insulation failures and fires
Prevents overheating due to unbalanced phases
Overtemperature (PTC) protection for high ambient or loss-of-ventilation detection
Detects unhealthy supply conditions
Detects catastrophic failures and fires; extends motor life
Detects low level or no-load conditions
Optional RTD temperature protection (PGA-0120 module) for high ambient or loss of ventilation protection
Limits the motor starts per hour to prevent overheating
Optional with PGA-0140 module allows sensitive winding-fault protection
Provides protection through starting, running, and cooling cycles
Remotely view measured values, event records & reset trips
Minimizes Arc-Flash hazards during maintenance
Alphanumeric display of conditions
Separate current input module to reduce risk of CT hazard and for convenient installation
Provides means for metering selectable parameters
On-board 100-event recorder for data logging
Internal circuits are conformally coated to protect against corrosion and moisture
RTD
POWR-GARD
PGA-0120
(Temperature
Input Module)
PAGe
38
41
41
41
®
M
C
RTD
®
21
Specifications
Protective Functions
(IEEE Device Numbers)
Input Voltage
Power-Up Time
Ride-Through Time
24-Vdc Source
AC Measurements
Frequency
Inputs
Output Contacts
Approvals
Communications
Conformally Coated
Warranty
Mounting
(Control Unit)
(Current Input Module) DIN, Surface
Overload (49, 51)
Phase reverse (current) (46)
Overcurrent (50, 51)
Jam
Ground fault (50G/N, 51G/N)
Undercurrent (37)
PTC overtemperature (49)
65 – 265 Vac, 25 VA; 80-275 Vdc, 25 W
800 ms at 120 Vac
100 ms minimum
100 mA maximum
True RMS and DFT, Peak, 16 samples/cycle, and
positive and negative sequence of fundamental
50, 60 Hz or ASD
Phase-current, Earth-leakage current, Phase-voltage,
PTC-thermistor, 4 – 20 mA, programmable
Five contact relays — See Product Manual
CSA certified to US and Canadian standards
RS-485 with Allen-Bradley
(Standard); DeviceNet™, Profibus
Standard feature
10 years
Panel (standard)
Surface (with PGK-0SMK converter kit)
www.littelfuse.com/pgr-6200
®
RTD temperature (38, 49)
Unbalance (current) (46)
Starts per hour (66)
Phase loss (voltage) (47)
Overvoltage (59)
Differential (87)
Phase loss (current) (46)
DFI and Modbus
®
, Ethernet (Optional)
®
RTU

Related parts for PGR-6200-04-00-MPU