IEGH111-1-72-30.0-91-V AIRPAX, IEGH111-1-72-30.0-91-V Datasheet - Page 3

no-image

IEGH111-1-72-30.0-91-V

Manufacturer Part Number
IEGH111-1-72-30.0-91-V
Description
IEGH CIRCUIT BREAKER, ONE HANDLE PER POLE, THREE POLES, 30 AMPS
Manufacturer
AIRPAX
Datasheet

Specifications of IEGH111-1-72-30.0-91-V

No. Of Poles
3
Current Rating
30A
Interrupting Capacity
5kA
Dielectric Strength
3.75kV
Trip Time
60s
Rohs Compliant
Yes
107
Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] unless noted.
*See Single Pole Mounting Detail for hole sizes and locations. LEG type units are only
available in one or two poles.
MULTI-POLE CIRCUIT PROTECTORS
(IAG/IUG/IEG/CEG/LEG)
Two Pole Protectors
An assembly consisting of two single pole units, having their trip
mechanisms internally coupled and with a single toggle handle,
forms the IEG11 with quick-connect D.I.N.-style terminals.
Individual poles may differ in ratings, delays and internal
connections. An auxiliary switch may be included in either or
both poles, allowing you to mix SELV and hazardous voltages.
Rugged screw-type terminals can be provided, in which case the
designation would be IEG66. The IEGH offers a toggle handle for
each pole. LEG type units are avavailable only in one or two pole
configurations.
Three Pole and Four Pole Protectors
The three pole construction consists of three single pole units
assembled with an internal mechanical interlock which actuates
IAG /IUG /IEG /CEG/LEG
LEG Type Units Require Screw
Terminals
[38.86]
1.530
2.075
[52.71]
MAX.
.
[5.84]
230
IAG/IUG/IEG/CEG/LEG Series - Multi-Pole
1.687
[42.85]
.690
[17.53]
OFF
ON
.240
[6.10]
32º
32º
2X
[
15.88
.625
+.25
-.00
+.010
-.000
4X
[42.17]
1.660
[
[3.96]
.156
IAG/IUG/IEG/CEG/LEG Multi-Pole Circuit Breakers
[26.68]
1.050
Two Pole*
Two Pole*
(Optional: Handle may be
located in Pole 1 instead
of Pole 2)
O
N
[19.05]
O
F
F
1.515
[38.48]
MAX.
.750
Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters.
all units simultaneously. A single toggle handle operates all three
poles for quick and convenient control, or if preferred, a handle
per pole is available. The four pole construction consists of four
single pole units assembled with an internal mechanical
interlock which actuates all units simultaneously. A double
toggle handle operates all four poles. The individual poles need
not have identical characteristics and any series trip pole may
have an auxiliary switch. If screw-type terminals are required,
the breaker designation will be IEG666 for a three pole version
and IEG6666 for a four pole version.
Protector poles are numbered consecutively when viewed from
the terminal side, with the ON position up, starting with Pole #1
on the left side and proceeding to the right.
Three Pole*
Three Pole*
[19.05]
.750
O
N
2.265
[57.53]
MAX.
[19.05]
O
F
F
.750
Four Pole*
http://airpax.sensata.com/
Four Pole*
[19.05]
.750
O
N
[19.05]
O
F
F
.750
3.015
[76.58]
MAX.
O
N
[19.05]
O
F
F
.750
http://airpax.sensata.com/
MULTI-POLE CIRCUIT PROTECTORS
(IAGH/IUGH/IEGH/CEGH/LEGH)
The IAGH/IUGH/IEGH/CEGH/LEGH two, three and four pole
models are available with a handle per pole.
LEGH type units are available only in two pole models.
IAGH/IUGH/IEGH/CEGH/LEGH Protectors
Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] unless noted.
NOTE:
LEG/LEGH Barriers (required)
In order to meet UL listing requirements, the LEG/LEGH two
pole model requires barriers. Available with a standard
straight barrier or an optional “Z” type barrier.
Standard Barrier
LEG Type Units Require Screw Terminals
[38.86]
1.530
We recommend machining slots into your panel for 2 or more poles. This eliminates the need to dissemble/reassemble the handle ties to be able to insert the handles thru
indvidiually drilled holes. LEG type units are only available in one or two poles.
2.075
[52.70]
MAX.
Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters.
.
[5.84]
230
1.687
[42.85]
.690
[17.53]
OFF
ON
.240
[6.10]
32º
32º
[50.80]
[50.80]
2.000
2.000
2X
2X
+.010
+.010
15.87
15.87
-.000
-.000
.625
+.25
.625
+.25
[31.00]
[31.00]
-.00
-.00
1.220
1.220
2X
2X
[42.16]
[42.16]
[4.27]
[4.27]
1.660
1.660
.168
.168
4X
4X
Two Pole
[42.16]
[42.16]
[15.00]
[15.00]
1.660
1.660
MAX.
MAX.
.590
.590
[3.96]
[3.96]
[26.67]
[26.67]
.156
.156
1.050
1.050
4X 6 – 32 THREAD
.140 [3.56] DEEP
M3 ISO THD. OPTIONAL
4X 6 – 32 THREAD
.140 [3.56] DEEP
M3 ISO THD. OPTIONAL
O
N
O
N
[19.05]
[38.48]
[38.48]
[19.05]
1.515
1.515
O
F
F
O
F
F
.750
.750
O
N
O
N
MAX.
MAX.
O
F
F
O
F
F
Optional “Z” Barrier
IAG/IUG/IEG/CEG/LEG Series - Multi-Pole
*See Two Pole Mounting Detail for hole sizes and locations.
O
N
O
N
Three Pole*
[19.05]
[19.05]
O
F
F
O
F
F
.750
.750
[57.53]
[57.53]
O
N
O
N
2.265
MAX.
2.265
MAX.
[19.05]
[19.05]
O
F
F
O
F
F
.750
.750
O
N
O
N
O
F
F
O
F
F
O
N
O
N
[19.05]
[19.05]
Four Pole*
O
F
F
O
F
F
.750
.750
O
N
O
N
[19.05]
[19.05]
[76.58]
[76.58]
O
F
F
O
F
F
3.015
3.015
MAX.
MAX.
.750
.750
O
N
O
N
[19.05]
[19.05]
O
F
F
O
F
F
.750
.750
O
N
O
N
O
F
F
O
F
F
108

Related parts for IEGH111-1-72-30.0-91-V