4404.0010 Schurter Inc, 4404.0010 Datasheet

no-image

4404.0010

Manufacturer Part Number
4404.0010
Description
CBE T9-611P-15
Manufacturer
Schurter Inc
Series
T9r
Type
Thermalr
Datasheets

Specifications of 4404.0010

Breaker Type
Thermal
Voltage
32/48VDC, 240VAC
Current - Trip (it)
15A
Number Of Poles
1
Actuator Type
Push to Reset
Mounting Type
Panel Mount
Alt Mfr.s Type
T9-611P-15
Brand/series
T9-611 Series
Current, Rating
15 A
Dimensions
34mmLx19mmWx19mmH
Mounting Hole Size
16 mm
Termination
Quick Connect
Voltage, Rating
240/32 VAC/VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
4404.001
T9-611P-15
T9-611P-15
Resettable Thermal Circuit Breaker, Single Pole, 3 – 16 A
Description
– Thermal circuit breaker
– Supplementary protector for general industrial use
– Cycling trip-free release
– Reset type
– Single pole
– Mounting style: T9-211: Threaded neck with nut PA 66
Standards
– IEC 60934
– UL 1077
– CSA C22.2 235 (3– 16 A)
– GB 17701
Technical Data
Typical internal resistance
Circuit breakers
Rated voltage
Rated current
Conditional short circuit capacitiy
Overload rating
Degree of protection
Endurance minimum
Endurance typical
Dielectric strength
Insulation resistance
Ambient temperature
Type of actuation
Type of tripping
Weight
T9-211: Threaded neck
with nut PA 66
Rated current
3 A
4 A
5 A
6 A
7 A
8 A
T9-311: Threaded neck with nut nickel plated
T9-611: Snap-in front side
T9-711: Snap-in rear side
(4 –16 A)
(3– 16 A)
(4 –16 A)
Internal resistance
(mΩ)
65.0
21.6
23.6
16.3
15.3
12.9
T9-311: Threaded neck
with nut nickel plated
(see approvals)
IEC: Inc, PC1, AC 240 V
UL / CSA: SC, AC 240 V / DC 48/32 V
UL / CSA
Accessible range
Termination range
IEC: 200% In, cos phi 0.6
3 – 8 A: 150% In, cos phi 0.9
10 –16 A: 150% In, cos phi 0.9
DC 500 V
5–16 A
4 A
3 A
Reset Type (manual)
Rated current
10 A
12 A
14 A
15 A
16 A
circuit breakers
Internal resistance
(mΩ)
Applications
– Power supplies
– UPS
– Power tools
– Household appliances
– Industrial appliances
– Medical diagnostic appliances
– HVAC
Weblinks
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
7.3
7.0
4.8
4.3
3.9
T9-611: Snap-in from front side
www.schurter.com/pg17_18_19
AC 240 V, 50/60 Hz
DC 48/32 V
3 –16 A
2 kA
2 kA, C1
OL0 240 VAC
OL0 48 VDC and 32 VDC
IP 40
IP 00
min. 50 cycles
2500 cycles
6000 cycles
AC 1500 V
> 1000 MΩ
-30 °C to 60 °C
-30 °C to 50 °C
R
Cycling trip-free
9 – 13 g
-5 °C to 60 °C
T9-711: Snap-in from back side
1
T9

Related parts for 4404.0010

4404.0010 Summary of contents

Page 1

Circuit breakers Resettable Thermal Circuit Breaker, Single Pole, 3 – T9-211: Threaded neck T9-311: Threaded neck with nut PA 66 with nut nickel plated Description – Thermal circuit breaker – Supplementary protector for general industrial use – Cycling ...

Page 2

T9 www.schurter.com/pg17_18_19 Tripping Characteristics [min] [sec] 10'000 1'000 100 0 Multiple of Rated Current Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. ...

Page 3

Circuit breakers Order Code Accessories Protection cover TZZ31 for IP 65 for type T9-211/311: 13.6 Hexagonal nut TZZ12 / TZZ51: 3/8"-27UNS 2.5 Order number Type description 4404.0039 TZZ31 Protection cover for IP 65 ...

Page 4

T9 www.schurter.com/pg17_18_19 Dimensions T9-211/311 ±0.3 ø 15.4 8 9.6 8.9 Panel thickness S = 0.8–5.5 mm T9-611 ±0.3 ø 15.4 8 +0.15 +0. Panel thickness S = 0.8–2.0 mm T9-711 ±0.3 ø 15 13.9 -0.1 ...

Related keywords