GTCA26-101M-P02 Tyco Electronics, GTCA26-101M-P02 Datasheet - Page 2

no-image

GTCA26-101M-P02

Manufacturer Part Number
GTCA26-101M-P02
Description
GAS DISCHARGE TUBE, 2P, 3KA, 700V
Manufacturer
Tyco Electronics
Series
GTCx26r
Datasheets

Specifications of GTCA26-101M-P02

Suppressor Type
Gas Discharge Tube (GDT)
Dc Breakover Voltage
100V
Impulse Sparkover Voltage
700V
Gdt Case Style
Axial Leaded
Impulse Discharge Current
90A
Spark Over Voltage
100V
Tolerance
±20%
Package / Case
Axial
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
308 Constitution Drive
Menlo Park, CA 94025-
1164
Phone: 800-227-4856
www.circuitprotection.com
PART NUMBERING
EXAMPLE:
DEVICE MARKING
EXAMPLE : GTCA26-231M-P05
Series
GT : Gas Tube
Material
C : Ceramic
Type
N : No Leads
A : Axial Leaded
Number of Electrodes
2 : Two
Diameter
6 : 6mm
23 P 05 GN
Week of Manufacture
Surge Rating:
Product Family
Voltage Designator
Manufacturer Marking
Per Raychem Circuit Protection
lot number system :
E.g. G = First half of 2004; N = week 14
02 : 2.5kA
05 : 5kA
10 : 100 V
23 : 230 V
35 : 350 V
Miniature Two Electrode Series
Raychem Circuit Protection Products
GT C N 2 6 - 101 M - P 02 -B
Overvoltage Protection Device
Gas Discharge Tube
Packaging
No Suffix: Tray packaging for GTCA
-B: Bulk packaging for GTCN
Surge Rating
02: 2kA (10 times 8 x 20μs)
05: 5kA (10 times 8 x 20μs)
Product Family
Voltage Tolerance
M: ± 20%
Voltage Designator
101 : 10 x 10 ^ 1 = 100V
231 : 23 x 10 ^ 1 = 230V
351 : 35 x 10 ^ 1 = 350V
PRODUCT: GTCx26
DOCUMENT: SCD 25817
REV LETTER: E
REV DATE: JULY 8, 2008
PAGE NO.: 2 OF 5

Related parts for GTCA26-101M-P02