FRS-R-100 Cooper/Bussmann, FRS-R-100 Datasheet - Page 2

FUSE, 100A, 600V, TIME DELAY

FRS-R-100

Manufacturer Part Number
FRS-R-100
Description
FUSE, 100A, 600V, TIME DELAY
Manufacturer
Cooper/Bussmann
Series
FRS-Rr
Type
Time Lagr
Datasheets

Specifications of FRS-R-100

Voltage Rating Vdc
300V
Voltage Rating Vac
600V
Fuse Current
100A
Blow Characteristic
Time Delay
Fuse Size Imperial
1.11 X 7.88"
Length
139.7mm
Fuse Terminals
Blade
Diameter
26.99mm
Brand/series
Fusetron®/FRS-R Series
Class
Class RK5
Current, Rating
100 A
Current, Ratings
100 A
Dimensions
1.11x7.88 "
Material, Body
Fiberglass
Mounting Type
Stud
Primary Type
Cylinder
Size
60A
Termination
Cartridge
Voltage, Rating
600/300 VAC/VDC
Dual-element, Time Delay
10 Seconds (Min.) at 500% Rated Current
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Catalog Symbol:
Dual-Element, Time-Delay – 10 seconds (minimum) at 500%
Current-Limiting
Ampere Rating: 65 to 600A
Voltage Rating: 600Vac (or less)
Interrupting Rating: 200,000A RMS Sym.
dc Ratings (20,000AIC @ 300Vdc)
Agency Information:
UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-01, File 53787
Catalog Numbers
FRS-R-65
FRS-R-70
FRS-R-75
FRS-R-80
FRS-R-90
FRS-R-100
FRS-R-110
FRS-R-125
Carton Quantity and Weight
Ampere
Ratings
65–100
101–200
201–400
401–600
*Weight per carton.
Fusetron
Dual-Element, Time-Delay Fuses
Class RK5 –– 600 Volt
12-27-02
rated current
To obtain information for 0-60A, access Data Sheet: 1017
A02125
Carton
Qty.
1
1
1
1
FRS-R
®
FRS-R-135
FRS-R-150
FRS-R-175
FRS-R-200
FRS-R-225
FRS-R-250
FRS-R-275
FRS-R-300
Recommended fuseblocks for
Class R 600V fuses
See Data Sheet: 1111
Lbs.
0.54
1.22
3.00
5.00
Weight*
FRS-R-325
FRS-R-350
FRS-R-400
FRS-R-450
FRS-R-500
FRS-R-600
0.245
0.544
1.359
2.268
Kg.
Dimensional Data
Dimensions
Ampere Ratings
110-200
225-400
450-600
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips
200A
400A
600A
*Single reducer only (pair not required).
For additional information, see Data Sheet: 1118.
General Information:
• Provides motor overload, ground fault and short-circuit
• The time-delay feature makes it possible to use fuse ampere
• Provides a good degree of short-circuit protection (greater
• Gives motor running back-up protection to motors without
• Helps protect motors against burnout from overloads and
• Simplifies and improves blackout prevention (selective
• Dual-element fuses can be applied in circuits subject to
65-100
protection. When used in circuits subject to surge currents
such as those caused by motors, transformers and other
inductive components, these fuses can be sized close to
full-load amperes to give maximum overcurrent protection.
of smaller size switches, panels and fuses themselves.
current-limitation) to help protect downstream components
from high fault currents.
extra costs.
single phasing when sized properly.
coordination ratios).
temporary motor overloads and surge currents to provide
both high-performance, short-circuit and overload protection.
ratings which are much smaller than those of non-time-delay
fuses. Considerable cost saving occurs by permitting the use
(inches)
Fuse (Case)
Desired
11.63 (± 0.094)
13.38 (± 0.094)
7.88 (± 0.062)
9.63 (± 0.062)
100A
100A
200A
100A
200A
400A
Size
A
A
Bussmann
Catalog Number
1.11 (± 0.020)
1.61 (± 0.020)
2.34 (± 0.020)
2.88 (± 0.020)
Form No. FRS-R 70-600
No. 2621-R
No. 2641-R
No. 642-R
No. 2661-R
No. 2662-R
No. 2664-R*
65-600A
(Pairs)
600V
FRS-R
B
Data Sheet: 1018
Page 1 of 3
B
®

Related parts for FRS-R-100