HPC-D Cooper/Bussmann, HPC-D Datasheet

FUSE HOLDER, 10.3 X 38MM, PANEL MOUNT

HPC-D

Manufacturer Part Number
HPC-D
Description
FUSE HOLDER, 10.3 X 38MM, PANEL MOUNT
Manufacturer
Cooper/Bussmann
Datasheet

Specifications of HPC-D

Voltage Rating Vac
600V
Fuse Current
20A
Fuse Holder Type
Fuse Holder
Holder Terminals
Quick Connect
No. Of Fuses
1
Fuse Size Held
13/32 X 1.1/2"
Fuse Size Imperial
13/32 X 1.1/2"
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Catalog Symbol: HPC-D
Panel-Mount
Agency Information:
UL Recognized, Guide IZLT2, File E14853
Flammability Rating: UL 94 HB
Electrical Ratings
Catalog
Symbol
HPC-D
(1) No UL Recognition
(3) 20A max when used with quick-connect terminals.
Replacement knob -BK/9987SA
Panel-Mount Fuseholder
For ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
6-3-04
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
Amps
30 (3)
SB04184
Volts AC
600
Description
Dimensional Data: All other dimensions (±0.015).
Maximum panel thickness, mounting flange in front of panel
Assumes Pollution Degree 3 per UL 840:
Maximum panel thickness not including any sealing gaskets.
System Voltage
Fuseholder
HPC-D
Thicker panels may be used if fuse holder load terminal is fully insulated, using a
UL recognized (VW-1) insulative heat-shrink tubing, or if anticipated environment
is of Pollution Degree 1 or 2, or if panel is nonconductive.
Pollution Degree 2- Normally, only nonconductive pollution. However, a temporary
Pollution Degree 1- No pollution or only dry, nonconductive pollution.
Maximum panel thickness, mounting flange behind the panel:
General Information:
• Screw-type knob.
• Supplied with “O”-ring and panel gasket.
• Military version designated FHN23W.
• Do not put tension on line (rear) terminal.
Mounting Hole
Flange Rear of Panel
Conductive pollution, or dry, nonconductive pollution that
becomes conductive due to condensation that is expected.
conductivity caused by condensation may be expected.
The pollution has no influence.
5.08mm/0.200” (flush to knob collar)
(33.3mm + 0.08mm)
(30.5mm)
1.312" + 0.003"
1.120"
(45.1mm)
1.775"
mm Inches mm Inches mm Inches mm Inches mm Inches
**
(4.6mm)
0.180"
600V
(26.2mm + 0.08mm)
1.031" + 0.003"
**
(4.75mm + 0.05mm)
0.187" + 0.002"
(22.6mm
0.87 1/32” 5.14 3/16” 5.69 7/32” 7.17 9/32”
0.890"
480
+
+
0.08mm)
0.003"
2.48" Max.
With Fuse
(63.1mm)
(22.2mm)
0.88"
Mounting Hole
Flange Front of Panel
277
(33.3mm + 0.08mm)
1.312" + 0.003"
Bussmann
240
HPC-D
Data Sheet: 2109
Form No. HPC-D
Page 1 of 1
120
®

Related parts for HPC-D

Related keywords