Fuseholders
Description
- Mounting from rear-side
Standards
- IEC 60127-6
- UL 512
- CSA C22.2 no. 39
Approvals
- VDE License Number: 127216
- UL File Number: E39328
Technical Data
Shocksafe Category
Fuse-Link
Mounting
Fastening
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC 2.5 W / 10 A @ Ta 23 °C
Degree of Protection
Protection Class
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
Material: Socket
Material: Terminals
Unit Weight (Socket/Cap)
Storage Conditions
Product Marking
Dimensions
Variants 3101.0020 and 3101.0220
Shock-Safe Fuseholder, 5 x 20 mm, Slot/Fingergrip, Rear-Side, IP 40 / IP 67
250 VAC · 2.5 W / 10 A (VDE) · 16 A (UL/CSA)
13.5
8
M12.7x1.5
SW14
41.5
2.5
20
PC2
5 x 20 mm
Panel Mount, Rear-Side
Fixing Nut
Solder or Quick-Connect 4.8 x 0.5 mm
250 VAC
10 A (VDE), 16 A (UL/CSA)
Admissible power acceptance at hig-
her ambient temperature see derating
curves
IP 40 / IP 67
Suitable for appliances with protection
class I or II acc. to IEC 61140
40/085/21 acc. to IEC 60068-1
Thermoplastic, black, UL 94V-0
Tin-Plated Copper Alloy
6.01 g
0 °C to 60 °C, max. 70% r.h.
Current Rating, Approvals
Length
, Type, Voltage Rating, Power Acc./
8
Fingergrip
6
Variants Fingergrip 3101.0025 and 3101.0225
References
General Product Information
Weblinks
Approvals: www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
CHINA-RoHS: www.schurter.com/china-rohs
Webstore: www.schurterinc.com/estore/search.ihtml
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Admissible Torque on Fixing
Nut
Panel Thickness s
Fuses
46.5 mm
www.schurter.com/pg02
4
18.5
13.5
8
M12.7x1.5
46.5
SW14
41.5
2.5
20
Iron
350 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 2
350 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 2
< 5 mW at 20 mV
> 3 kV between L-N
> 4 kV between L/N-PE
(50 Hz; 1 min)
> 4 kV between L-N
> 6 kV between L/N-PE
> 10 MW between L-N
> 100 MW between L/N-PE
(500 VDC; 1 min)
I - III acc. to IEC 60664-1
1 - 3 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
max 1.2 Nm
max 8 mm
8
6
FPG2