QO112M100 SQUARE D, QO112M100 Datasheet - Page 22

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
QO
Technical Information
22
Single-Phase, Three-Wire, 120/240 Vac; Main Lugs
1
2
3
4
B UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) with field-installed service disconnect.
C UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) when not more than six service disconnecting means are provided and
Rating in
Fixed Mains – Factory-Installed Main Lugs
Convertible Mains – Factory-Installed Main Lugs
QOM1 Main Frame Size – Convertible to Main Circuit Breaker – Copper Bus
Convertible Mains – Factory-Installed Main Lugs
QOM2 Main Frame Size – Convertible to Main Circuit Breaker – Copper Bus
Mains
Amps
Convertible mains load center has a side-hinge door. Allow 1.25 in. (32 mm) on the left side for the door to open.
Short circuit current rating depends on lowest AIR rating of main or branch circuit breaker installed.
UL Listed at 5000 A rms symmetrical short circuit current rating when used in 3-phase, corner grounded, Delta systems, when used as main lugs load center only.
Use 240 Vac circuit breakers only.
22,000 A rms symmetrical maximum when supplied by integral type QOM-VH main circuit breaker from Square D
interrupting rating and when all QO
when not used as a lighting and appliance branch circuit panelboard. See NEC Article for Lighting and Appliance Branch Circuit Panelboard.
100
100
125
125
150
200
225
60
40
70
© 2007 Schneider Electric All Rights Reserved
and Homeline
QO2L40RB
QO24L60NRNM
QO24L70RB
QO612L100RB
QO612L100TRB
QO612L100RBCU
QO816L100RB
QO816L100RBCU
QO148L125GRB
QO112L125GRB
QO11224L125GRB
QO11624L125GRB
QO124L125GRB
QO130L150GRB
QO112L200GRB
QO130L200GRB
QO13040L200GRB
QO140L200GRB
QO142L225GRB
Catalog Number
Load Center
Load Centers and Enclosures
®
installed branch circuit breakers have 10,000 A rms symmetrical minimum interrupting rating.
Cover Catalog
Load Center
Number
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
1
(See Notes)
Equipment
UL Listed
Service
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B, C
B
B
B
Rainproof
Maximum UL
Short Circuit
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
Rating
2
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
Main Wire Size
AWG/kcmil
#12 2/ 0
#14 2/ 0
#14 10
#6 250
#6 250
#6 250
#6 250
#6 250
#6 300
#6 2 /0
#6 2 /0
#6 2 /0
#6 2 /0
#12 6
#14 4
#12 3
#14 4
Al/Cu
#8 1
#8 1
#8 1
#8 1
#8 1
®
Enclosure
(Page 27)
with 22,000 A rms symmetrical minimum
1NM
15R
No.
1R
1R
2R
2R
2R
2R
2R
3R
3R
4R
4R
6R
5R
6R
6R
7R
8R
or Bottom
Position
Mains
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Top
Corner Grounded
Delta Systems
UL Listed for
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
03/2007