PAQ50S48-1R8 TDK Corporation, PAQ50S48-1R8 Datasheet - Page 4

no-image

PAQ50S48-1R8

Manufacturer Part Number
PAQ50S48-1R8
Description
LAMBDA PART
Manufacturer
TDK Corporation

Specifications of PAQ50S48-1R8

Rohs Compliant
YES

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PAQ50S48-1R8
Manufacturer:
LAMBDA
Quantity:
33
Part Number:
PAQ50S48-1R8
Manufacturer:
TDK-LAMBDA
Quantity:
488
Part Number:
PAQ50S48-1R8/B
Manufacturer:
LINFINITY
Quantity:
50 000
Part Number:
PAQ50S48-1R8/B
Manufacturer:
LAMBDA
Quantity:
20 000
Part Number:
PAQ50S48-1R8/PV
Manufacturer:
LAMBDA
Quantity:
1 000
Part Number:
PAQ50S48-1R8/V
Manufacturer:
IR
Quantity:
1 000
PAQ
B-228
PAQ
PAQ100S48
(*1) Use an external fuse (fast blow type) for each unit.
(*2) Put output capacitors.
(*3) Refer to instruction manual for further details.
■ Basic Connection
Environment
Standards Safety Standards
Mechanical
Function
Isolation
ITEMS/UNITS
(*1) At 48VDC, maximum output current, air velocity = 2m/s and Ta = +25℃.
(*2) 36 - 76VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting. (The unit automatically shutdown when left in OCP condition
(*5) Inverter shutdown method, manual reset. Auto restart option available.
(*6) Refer to Instruction manual.
(*7) Refer to derating curve and Instruction manual.
(*8) External components are needed for operation. (Refer to basic connection and Instruction manual.)
Output
36-76VDC
Input
Vin
Measurement point for Vin
FUSE 6.3A
with the output voltage less than the LVP level.) Auto restart option available.
(*1)
C1: 1µF ceramic capacitor.
C2: 10µF tantalum capacitor or electrolytic capacitor.
Voltage Range
Efficiency (typ)
Current (typ)
Nominal Voltage
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation
Maximum Load Regulation
Temperature Coefficient
Maximum Ripple & Noise
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Remote Sensing
Remote ON/OFF Control
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Weight (typ)
Size (W x H x D)
100S48

CNT
-Vin
+Vin
Measurement point for
Vo, Load/Line regulation
TRM
+V
+S
-S
-V
L=50mm
(*2) mV
(*3) mV
(*8) mVp-p
(*8)
(*5)
(*6)
(*6)
(*6)
(*7)
(*7)
(*1)
(*1)
(*1)
(*4)
MODEL PAQ100S48-1R2 PAQ100S48-1R8 PAQ100S48-2R5 PAQ100S48-3R3 PAQ100S48-5
PAQ100S48-* Specifications
(*2)
%RH
%RH
VDC
mm
Measurement point for
output ripple & noise
(JEITA RC-9141 probe)
Bandwidth of scope : 100MHz
W
%
V
A
A
g
LOAD
-
+
0.8
1.2
80
30
Amplitude 0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 hour each
More than 100MΩ at 25℃ and 70%RH Input-Output...500VDC
Approved by UL60950-1, CSA 22.2 No.60950-1, EN60950-1
105% - 140% (Option availavle : Refer to option table)
120% - 140% (Option availavle : Refer to option table)
-20%, +10%
■ Option Table
Possible (Option availavle : Refer to option table)
Standard
1.14
Option
1.8
84
45
At no operating, 10-55Hz (sweep for 1min.)
/PV
36.8×8.5×57.9 (Refer to outline drawing)
/V
/P
Convection cooled / Forced air cooled
Input-Output : 1.5kVDC for 1min
25
Less than 0.02%/℃
5 - 95 (No dewdrop)
5 - 95 (No dewdrop)
(ON/OFF control reset or
(ON/OFF control reset or
Ta= -40 to +85
-40 to +100
DC36 - 76
196.1m/s²
Possible
Possible
manual reset)
manual reset)
62.5
1.55
100
Auto restart
Auto restart
2.5
±1
OVP, OCP
Shut down
Shut down
86
10
10
50
-
・All specifications are subject to change without notice.
1.98
82.5
3.3
89
Remote ON/OFF control
Open : OFF)
(Short : OFF,
(Short : ON,
±15%
Open : ON)
Negative
Positive
2.37
100
90
20
5