MTU1S1212MC-R Murata Power Solutions Inc, MTU1S1212MC-R Datasheet - Page 2

DC/DC SM 1W 12-12V Single 1kV

MTU1S1212MC-R

Manufacturer Part Number
MTU1S1212MC-R
Description
DC/DC SM 1W 12-12V Single 1kV
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of MTU1S1212MC-R

Product
Isolated
Output Power
1 W
Input Voltage Range
10.8 V to 13.2 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
83 mA
Isolation Voltage
1 KV
Package / Case Size
8.4 mm x 8.2 mm x 8.5 mm
Output Type
DC/DC Converter
Output Voltage
12 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1. Measured on centre of input side PCB.
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MTU1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specifi c agency approvals, such as the MTU1 series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MTU1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
TEMPERATURE DERATING GRAPH
RoHS COMPLIANCE INFORMATION
www.murata-ps.com
1.5
1.0
0.5
0
-40
Safe Operating Area
Ambient Temperature (°C)
0
50
This series is compatible with RoHS soldering systems with a peak refl ow solder temperature of 245ºC as per J-STD-020D.
The pin termination fi nish on this product series is Matte Tin over Nickel Preplate. The series is backward compatible with Sn/Pb soldering
systems. The series has a Moisture Sensitivity Level (MSL) 1.
Samples of the product series were tested in accordance with the conditioning described for MSL level 1 in IPS/JEDEC STD-020D.
The product series passed electrical tests and visual inspection criteria.
For further information, please visit: www.murata-ps.com/rohs
85°C
100
150
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance
envelope is the maximum output voltage variation due to changes in output loading.
TOLERANCE ENVELOPES
5V output types
5.5%
V
NOM
10
25
Output Load Current (%)
50
75
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
100
Isolated 1W Single Output SM DC/DC Converters
0%
-4%
1.5%
All other types
V
5%
NOM
10
2011-02-01 KDC_MTU.A03 Page 2 of 6
25
Output Load Current (%)
MTU1 Series
50
75
100
0%
-4%
1%

Related parts for MTU1S1212MC-R