CPCI-D-3U-300C Murata Power Solutions Inc, CPCI-D-3U-300C Datasheet - Page 2

DC/DC CPCI 300W 3Ux8HP

CPCI-D-3U-300C

Manufacturer Part Number
CPCI-D-3U-300C
Description
DC/DC CPCI 300W 3Ux8HP
Manufacturer
Murata Power Solutions Inc
Series
cPCI-D-3U-300Cr
Type
Isolatedr
Datasheet

Specifications of CPCI-D-3U-300C

Output
5V, 3.3V, ±12V
Number Of Outputs
4
Power (watts)
300W
Mounting Type
Compact PCI®
Voltage - Input
36 ~ 72V
Package / Case
Module
1st Output
5 VDC @ 30A
2nd Output
3.3 VDC @ 40A
3rd Output
12 VDC @ 5A
4th Output
-12 VDC @ 500mA
Size / Dimension
6.78" L x 1.59" W x 5.06" H (172.1mm x 40.3mm x 128.6mm)
Power (watts) - Rated
300W
Operating Temperature
-5°C ~ 55°C
Efficiency
81%
Approvals
CE, CSA, UL
Input Voltage
36 VDC to 72 VDC
Output Voltage (channel 1)
+ 5 V
Output Current (channel 1)
30 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
811-1965
ENVIRONMENTAL CHARACTERISTICS
Parameter
Ambient Operating Temperature
Ambient Storage Temperature
Operating Humidity
Storage Humidity
Altitude
GENERAL CHARACTERISTICS
Parameter
Effi ciency
Switching Frequency
MTBF
Weight
PROTECTION
Parameter
Inrush Current Limit
Input Protection
Over-voltage Protection
Parameter
Output Overload Protection
Hot-Swap Capability
Output Fault Isolation
Thermal Shutdown
STATUS & CONTROL SIGNALS & INDICATORS
Name
Enable (EN#)
Output Inhibit (INH#)
Output Fault (FAL#)
Remote Sense (RS+, RS-)
Thermal Warning (DEG#)
Front Panel Fault Indicator LED
Front Panel Power
www.murata-ps.com
Conditions/Response
230VAC
Internal line fuse
V1, V2, & V3 with latched shutdown
Conditions/Response
Outputs are individually protected against overloads and indefi nite short circuit with automatic recovery upon removal of the fault condition.
Protected by internal ORing diodes
Output isolation devices are present in all outputs to isolate faults within a failed power supply.
Automatic recovery upon restoration to operational temperatures
Description
Contact closure to external ground to start unit. On shortest pin (last make, fi rst break).
TTL –compatible signal inhibited with GND or TTL “0”.
TTL compatible signal, open collector active low signal. Indicates one or more outputs below 90% of specifi ed rate.
Available on V1 and V2. Maximum voltage compensation for cable losses 200mV
Open collector active low 10ºC before power supply shut down.
Red LED - indicates one or more outputs below 90% of specifi ed rate.
Green LED - indicates when mains input voltage present
Conditions
Full load with 250LFM forced air and derating linearly above 55°C to 70°C, by 2.5% per °C
Non-condensing
Non-condensing
Operating
Storage
Conditions
Full load, typical at 48Vdc
Main Converter
Calculated per Bellcore standard B332 Gb 30ºC
Unpackaged
cPCI-D-3U-300C Series
300W 3Ux8HP DC/DC CompactPCI™
Min
110
Min
-40
cPCI-D-3U-300C.A01 Page 2 of 4
-5
300
Min
Inception
Typ
Typ
730
Typ
81
90
40000
6000
Max
Max
130
6.3
50
55
85
95
95
Max
%V
Units
Units
A
A
Units
khrs
ºC
ºC
%
%
kHz
ft
ft
rms
rms
%
nom
g

Related parts for CPCI-D-3U-300C