PW-4080T TRUST, PW-4080T Datasheet

no-image

PW-4080T

Manufacturer Part Number
PW-4080T
Description
UPS, POWERMASTER 800VA, TRUST
Manufacturer
TRUST
Datasheet

Specifications of PW-4080T

Capacity (va / W)
800VA / 360W
No. Of Outlets
3
Output Voltage
230V
Backup Time - Full Load
35min
Length
338mm
Width
105mm
Height
147mm
Weight Min
6.7kg
External Depth
338mm
Weight
5.72kg
Ac Power
800VA
Approval Bodies
CE
PW-4040T/4050T/4060T/4080T 400VA/500VA/600VA/800VA UPS
Product information
Installation
Replacing fuse
Reminder
Specif
Model
Operation type
Output capacity
1 PC off
2
3
4 PC on
5 UPS completely off
6
UPS is charged only when AC power is supplied and UPS is on!
Fully discharge then recharge the battery every 3 months for longer battery life!
Connect incoming analogue phone line to D; Connect a telephone or modem to C!
Backup time is related to the connected devices and battery condition!
UPS does not have dial-up function nor smart management like message alarm!
Conductive device, like laser printer, is suggested to connect to the Surge Only output!
A: On/Off button
B: Status LED
Use power cable from PC to connect UPS to AC socket
Use loop through cable (I) to connect PC to UPS Backup output (H)
UPS on
battery power!
Open fuse holder
Replace a proper fuse at position A
ication
- AC power: Lit steady
- Battery power: Lit flash
Device connected to Surge Only output (G) does not get UPS backup!
UPS least 20cm away from monitor!
The UPS might be battery low due to its self-discharge characteristic; suggest to charge 8 hours before using
Use fuse of same rating (250V, 8A)!
(B) stores a backup fuse!
400VA /240W
14395
C: Phone/Modem out
D: Phone line in
E: AC input
F: Fuse holder
500VA / 300W
1
14422
Line Interactive
600VA /360W
G: Surge only output
H: Backup output
I: Loop through cables
14396
800VA /480W
14397
UK

Related parts for PW-4080T

PW-4080T Summary of contents

Page 1

... PW-4040T/4050T/4060T/4080T 400VA/500VA/600VA/800VA UPS Product information A: On/Off button B: Status LED - AC power: Lit steady - Battery power: Lit flash Installation 1 PC off Use power cable from PC to connect UPS to AC socket Use loop through cable (I) to connect PC to UPS Backup output (H) 2 Device connected to Surge Only output (G) does not get UPS backup! ...

Page 2

... PW-4040T/4050T/4060T/4080T 400VA/500VA/600VA/800VA UPS Input Voltage range Fr equency Output Frequency Freq. regulation Surge current protection [J] Maximum surge current [Amp] Transfer time (typical) Battery Battery type & number Or 6V Backup time (min.) Charge tim e Surroun Working dings surroundings Sound level Weight Minimum load ...

Page 3

... PW-4040T/4050T/4060T/4080T 400VA/500VA/600VA/800VA UPS • This UPS generates leakage curren t less than 0.5mA, please use in comfort. • The sum of the leakage current of the UPS and its connected equipments must • Do not open or repair this device. • Disconnect the power plug from the mains supply before cleaning the device. ...

Related keywords