S4K2U1500-C SOLA HEVI DUTY, S4K2U1500-C Datasheet
S4K2U1500-C
Specifications of S4K2U1500-C
Related parts for S4K2U1500-C
S4K2U1500-C Summary of contents
Page 1
Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (double- conversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time from external to internal power. When utility ...
Page 2
... Selection Table - S4K2U-C & S4K2U-5C Tower/Rack-Mount Models Capacity Catalog (VA/W) Number 120 Vac, 50/60 Hz Models 700/630 S4K2U700-C 1000/900 S4K2U1000-C 1500/1350 S4K2U1500-C 2000/1800 S4K2U2000-C 3000/2700 S4K2U3000-C 230 Vac, 50/60 Hz International Models 1000/900 S4K2U1000-5C 2000/1800 S4K2U2000-5C 3000/2700 S4K2U3000-5C * Full/Half Load (in minutes). contact Technical Services at (800) 377-4384 with any questions. ...
Page 3
... Full/half load (in minutes.) See selection table for more information. 2. Input power cord and receptacles can be removed for hardwired applications. contact Technical Services at (800) 377-4384 with any questions. 70 S4K2U1000-C S4K2U1500-C dimensions in. [mm] 19.7 x 16.9 x 3.4 [497 x 430 x 85] 25.5 x 23.9 x 10.6 [647 x 607 x 270] Weight, lb. [kg] 37 ...
Page 4
... Ambient temperature Maximum output power factor derating at maximum load contact Technical Services at (800) 377-4384 with any questions. Uninterruptible Power Systems S4K2U1000-C S4K2U1500-C <45 dBA max <46 dBA max ft front & sides; m] front & sides; <45 dBA <50 dBA max ft. ...
Page 5
Uninterruptible Power Systems S4K2U-5C, 230 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number Unit Shipping Unit Shipping Voltage Range (typical) 90% to 100% Loading 70% to 90% Loading 30% to 70% Loading 0% to 30% Loading Power Factor Frequency Input ...
Page 6
S4K2U-5C, 230 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number <43 dBA max ft.] front & Audible Noise sides; <46 dBA max ft.] rear Safety RFI/EMI Surge Immunity Transportation Operating Temperature Parameters ...
Page 7
... Storage Elevation Safety RFI/EMI Surge Immunity Transportation contact Technical Services at (800) 377-4384 with any questions. 74 S4K2U48BATC S4K2U700C, S4K2U1000C (-5), S4K2U1500C, S4K2U2000C (-5) dimensions in. [mm] 19.7 x 16.9 x 3.4 [497 x 430 x 85] 24.3 x 22.4 x 10.3 [617 x 570 x 262] Weight, lbs. [kg] 70.5 [32.0] 77.2 [35.0] Battery Valve-regulated, non-spillable, lead acid ...
Page 8
S4K2U-C and S4K2U-5C Battery Back-up Times Number of Model 200 Batteries VA 1 700 1000 Internal battery 1500 2000 3000 700 126 1000 128 Internal battery + 1 1500 external battery cabinet 2000 3000 700 264 1000 252 Internal battery ...