POWER SUPPLY, SWITCH MODE, 15V

MSA150012A

Manufacturer Part Number
MSA150012A
Description
POWER SUPPLY, SWITCH MODE, 15V
Manufacturer
Elpac
Datasheet

Specifications of MSA150012A

Power Supply Type
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
12V
Output Current
12.5A
Power Rating
150W
Input Voltage
85V AC To 264V AC
Length
127mm
Width
76.2mm
Product
Switching
Commercial/medical
Medical
Output Power Rating
180 W
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
12.5 A, 15 A
Mounting Style
Chassis
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A
949-777-6395
saleselpac@iccus.com
www.iccus.com
+44.1383.432921
saleseurope@iccus.com
As a Global Supplier of Power Sup-
plies, we are committed to meet-
ing energy efficiency standards
around the world. That is why we
have partnered with the ENERGY
STAR® Program and engineer our
Elpac Power Systems
strict energy-efficiency guidelines
established by the EPA and the US
department of Energy (dOE). The
Energy Star program has devel-
oped International partnerships
with countries and organizations
in major global markets. Those
participating in the program
include Australia, Canada, Euro-
pean Union, European Free Trade
Association, Japan, New Zealand,
and Taiwan.
Furthering our International com-
mitment, we have signed the EU
Code of Conduct on Efficiency
of External Power Supplies. Our
Elpac Power Systems
series meets the efficiency stan-
dards of the International ENERGY
STAR® program and the EU Code of
Conduct.
TECHNICAL SUPPORT
WORLdWIdE
EUROPE
ENERGY STAR PARTNER
TM
TM
to meet
MSA150
Notes
**Ripple and noise measured with 20MHz bandwidth; 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor.
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Zero Load
Power Consumption
Earth Leakage Current
Patient Leakage Current
*visit www.iccus.com for complete details
5-YEAR LIMITEd WARRANTY
85 – 264VAC
100 – 240VAC Nominal
47 – 63Hz
<2A rms
<37A at 230VAC cold start
>0.97
<0.5W
<150µA @ 132VAC @ 60Hz
<250µA @ 264VAC @ 60Hz
<50µA @ 132VAC @ 60Hz
<75µA @ 264VAC @ 60Hz
*
MSA 150 Series
Medical Switch Mode Power Supply
Output
Output Voltage
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection
·
·
·
·
·
·
·
·
·
High Efficiency
Up to 180W with Forced Air
High Power density 9.8W/in³
Lifetime Expectation >5 years
Hold-Up Time >25ms at full load
Medical Approval - EN60601-1 Class I
Energy Star Level V
EISA Compliant
CEC Compliant
See Table
+/-5%
No minimum load required
<1.5s
>25ms at any
input voltage
<1% pk-pk **
110 – 135%
Active - Recoverable; plus
Passive - Non Recoverable
120 – 180%
Shutdown, auto-restart
(hiccup mode)
150 Watts

Related parts for MSA150012A

MSA150012A Summary of contents

Page 1

... Taiwan. Earth Leakage Current Furthering our International com- mitment, we have signed the EU Code of Conduct on Efficiency Patient Leakage Current of External Power Supplies. Our Elpac Power Systems TM MSA150 series meets the efficiency stan- Notes dards of the International ENERGY *visit www.iccus.com for complete details STAR® ...

Page 2

... Model Number Output Voltage MSA150012A 12.0V MSA150015A 15.0V MSA150018A 18.0V MSA150024A 24.0V Notes 1) With convection cooling. Peak load (180W) lasting up to 500ms with a maximum 10% duty cycle. 2) Sustained output current with minimum 200 LFM 3) Includes initial setting, line regulation, load regulation, and thermal drift. ...