POWER SUPPLY, AC/DC, 5V

KMS15-5

Manufacturer Part Number
KMS15-5
Description
POWER SUPPLY, AC/DC, 5V
Manufacturer
TDK Corporation
Datasheet

Specifications of KMS15-5

Power Supply Type
Power Module
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
5V
Output Current
3A
Power Rating
15W
Input Voltage
90V AC To 264V AC / 100V DC To 375V DC
Length
64.008mm
Output Current (max)
3A
Number Of Outputs
1
Output Power (max)
15W
Input Frequency
47 to 440Hz
Efficiency
78%
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Pin Count
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMS15-5
Manufacturer:
TDK-LAMBDA
Quantity:
253
Notes:
(1) For medical applications an equivalent external fuse should be installed in the neutral line
(2) Class I Applications: An external filter can be added to meet EN55011 Class B - see application notes
KM Series
15 to 40W Medical AC-DC
PCB - Mount Power Supplies
ITEMS
Input Voltage Range
Inrush Current Limiting
Input Current (115 / 230VAC)
Internal Fuse (live line)
Temperature Coefficient (O/PV)
Ripple and Noise (pk-pk)
Overcurrent Protection
Overvoltage Protection
Hold-up Time (typical)
Enclosure Leakage 240Vac, 63Hz
Operating Temperature
Storage Temperature
Humidity
Cooling
Withstand Voltage
Immunity
Safety Agency Certification
Conducted EMI
Switching Frequency
Weight
Size (LxWxH)
Mounting & Case
MTBF
Warranty
KM Features and Benefits
Features
• Small Size
• Wide Input Range
• High efficiency
Specifications
264Vac, 63Hz
(1)
MODELS
%RH
VAC
kHz
mm
mA
mV
mA
mA
ms
hrs
yrs
%
A
g
-
-
-
-
-
-
-
-
-
-
-
KMS15
-25°C to 70°C, derate linearly to 50% load from 50°C to 70°C. Max case temperature 95°C
KM Series
EN55011 Class B
220 / 118mA
Benefits
• Minimises PCB Space
• Global use with no manual intervention
• Lower Heat Dissipated in System
250V/T2A
64 x 46 x 24
Convection, over temperature protected ~100°C case temperature)
0.055 max
0.06 max
KMD15
PC board mountable. Plastic resin fibreglass case (UL 94V-0)
20ms
120
10 / 20A, cold start, 25°C ambient (115 / 230VAC)
200,000 to 400,000 hours, model dependent
> 105%, hiccup mode, automatic recovery
90-264VAC 47-440Hz or 100-375VDC
UL60601-1, IEC60601-1, CE Mark
20% to 95% RH (non-condensing)
50mV or 1%, whichever is greater
• Small Size & Lightweight
• PCB Board Mountable
• Wide Range Input
• Medical Safety Certifications (4kVAC Input - Output)
• Class II (No ground needed)
Key Market Segments & Applications
Portable Medical Equipment
General Low Power Applications
KMT15
Yes, Zener diode clamp
Input to output: 4kVAC
-40°C to 100°C
EN60601-1-2
±0.01%/°C
132kHz
2
KMS40
EN55011 Class A
250V/T3.15A
860 / 460mA
89 x 64 x 27
0.085 max
0.08 max
KMD40
18ms
280
(2)
KMT40
1

Related parts for KMS15-5

KMS15-5 Summary of contents

Page 1

... Key Market Segments & Applications Portable Medical Equipment General Low Power Applications Benefits • Minimises PCB Space • Global use with no manual intervention • Lower Heat Dissipated in System KMS15 KMD15 KMT15 90-264VAC 47-440Hz or 100-375VDC 10 / 20A, cold start, 25°C ambient (115 / 230VAC) 220 / 118mA 250V/T2A ± ...

Page 2

... Model Selector Output Minimum Model Voltage Current (V) (A) Single Output KMS15-3P3 V1 3.3V 0A KMS40-3P3 V1 3.3V 80mA KMS15 KMS40 80mA KMS15 KMS40 44mA KMS15-12 V1 12V 0A KMS40-12 V1 12V 33mA KMS15-15 V1 15V 0A KMS40-15 V1 15V 26.7mA KMS15-24 V1 24V 0A KMS40-24 V1 24V 16.7mA Dual Output KMD15-55 V1 +5V 150mA ...

Page 3

M Outline Drawing KM15 Series M Outline Drawing KM40 Series Notes: (1) Symmetrical loading, from minimum to maximum load Derating Curves KM15 Series 100% 90% 80% 70% 60% 50% 40% 30% 20% 10 ...

Page 4

TDK-LAMBDA EMEA TDK-Lambda France SAS ZAC des Delaches BP 1077-Gometz-le-Chatel 91940 Les Ulis France Tel: + Fax: + france@fr.tdk-lambda.com www.fr.tdk-lambda.com Italy Sales Office Via dei Lavoratori 128/130 20092 Cinisello Balsamo ...

Related keywords