CU15-14 XP POWER, CU15-14 Datasheet

POWER SUPPLY, SWITCH MODE, 24V

CU15-14

Manufacturer Part Number
CU15-14
Description
POWER SUPPLY, SWITCH MODE, 24V
Manufacturer
XP POWER
Datasheet

Specifications of CU15-14

Power Supply Type
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
630mA
Power Rating
15W
Input Voltage
85V AC To 264V AC / 120V DC To 370V DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
10-15 Watts
CU10-15 Series
Specification
Input
Output
1
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current • Class 2 (no earth)
Input Protection
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 130-150% of Vnom, recycle input to reset
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 85-264 VAC (120-370 VDC)
• 47-63 Hz
• 0.13 A rms at 230 VAC (CU10)
• 20 A at 115 VAC, 40 A at 230 VAC,
• 1A fuse (CU10)
• See table
• ±5%
• ±1%
• No minimum load required
• 1.5 s max
• 14 ms max
• 16 ms typical at full load and 115 VAC
• 0.6%
• 0.5% max
• 1.0% max 10% load to full load
• 4% max deviation, recovery to within 1%
• 1% max pk-pk (see note 1)
• 0.05%/˚C
0.20 A rms at 230 VAC (CU15)
cold start 25 ºC
2A fuse (CU15, CU15-M)
within 500 µs for 25% load change
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
Operating Temperature • CU10/15: 0 ˚C to +65 ˚C, derate from
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Vibration
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & interruptions
Safety Approvals
Low Cost
Small Size
PCB Mount
15 Watt Medical Version
Single Output 3.3-24 V
Peak Load Capability
Non-standard Outputs Available
• See tables
• 3000 VAC Input to Output (CU10/15)
• 100 kHz typical for 10 W models
• 2.43 W/in
• >500 kHrs per MIL-HDBK-217F
• Convection-cooled
• 95% RH, non-condensing
• -20 ˚C to +85 ˚C
• 3000 m
• 10 Hz to 500 Hz, 2 g for 10 mins/cycle
• CU15-M: EN55011 Level B conducted
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-3, level 3, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, 10 V, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
• CU15-M: EN60601, UL2601-1, CSA22.2
4000 VAC Input to Output (CU15-M)
(15 & 24 V units >400 kHrs)
60% 1000 ms, 100% 5000 ms,
Perf Criteria A, B, B
No. 601.1 per cUL
Others: EN60950, UL1950, CSA22.2 No.
234 per cUL
67 kHz typical for 15 W models
full load at +45 ˚C to no load at +65 ˚C
CU15-M: 0 ˚C to +70 ˚C, derate from
full load at +50 ˚C to 50% load at +70 ˚C
60 min each cycle
Others: FCC20780 Level B,
EN55022 Class B conducted
3
(CU10); 3.17 W/in
xppower.com
3
(CU15)

Related parts for CU15-14

CU15-14 Summary of contents

Page 1

... V units >400 kHrs) Environmental Operating Temperature • CU10/15: 0 ˚C to +65 ˚C, derate from full load at +45 ˚ load at +65 ˚C CU15-M: 0 ˚C to +70 ˚C, derate from full load at +50 ˚C to 50% load at +70 ˚C Cooling • Convection-cooled Operating Humidity • ...

Page 2

... CU10-12 75% CU10-13 78% CU10-14 Efficiency Model (typical) Number 70% CU15-00 73% CU15-10 75% CU15-09 80% CU15-12 80% CU15-13 82% CU15-14 CU15/CU15-M models 0.07 (1.78) **Note: CU15-M models 0.04 (1.02) 0.07 (1.78) height 0.99 (25.2) **Note: CU15-M models 0.04 (1.02) height 0.99 (25.2) -Vo - +Vo + 0.157 (4.0) 2.441 (62.0) 2.75 (69.9) ...