MA3145-230-1-R MTL SURGE TECHNOLOGIES, MA3145-230-1-R Datasheet - Page 4

SURGE PROTECTOR, 1 PHASE

MA3145-230-1-R

Manufacturer Part Number
MA3145-230-1-R
Description
SURGE PROTECTOR, 1 PHASE
Manufacturer
MTL SURGE TECHNOLOGIES
Series
MA3100r
Datasheet

Specifications of MA3145-230-1-R

Suppressor Type
Mains
Voltage Rating
230VAC
Peak Surge Current
10kA
Response Time
25ns
Control Voltage Ac Max
230V
Current Id Max
10kA
External Depth
18mm
External Length / Height
65mm
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
T T o o o o r r d d e e r r C C l l a a s s s s I I I I s s u u r r g g e e p p r r o o t t e e c c t t i i o o n n d d e e v v i i c c e e s s , , s s p p e e c c i i f f y y - -
C C l l a a s s s s I I I I I I S S u u r r g g e e P P r r o o t t e e c c t t i i o o n n D D e e v v i i c c e e
The MA15 Series of surge protection devices has a unique ‘three stage’ combination of protection elements, that
suppress conducted RFI and voltage surges. The current elements are first, surge clipping components to absorb
transient surges that may otherwise damage equipment, second a filter to suppress noise in the system and third,
‘ring’ suppression. The third of these prevents surges causing the filter to ‘ring’ (oscillate) under low load conditions
-- an effect that actually accentuates interference in most commercially available filters.
The MA15 Series protects electronic equipment and computer networks against the effects of ‘noise pollution’
induced in power supplies. MA 15 units ‘clean up’ the effects of industrial noise and surges caused by lightning,
switching devices, thyristor controls, transmission system overloads and power-factor correction circuits.
Note: MA30 with 30A maximum load current also available.
MTL Surge Technologies offers a very wide range of surge
protection devices for AC power systems. Product series
such as the ZoneMaster, ZoneSentinel and ZoneDefender
offer extremely high levels of protection and are ideally
suited for the most critical industrial applications. Please
visit www.mtlsurge.com for more information.
M M T T L L S S u u r r g g e e T T e e c c h h n n o o l l o o g g i i e e s s
Power Court, Luton, Bedfordshire, England LU1 3JJ
Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283
E-mail: enquiry@mtlsurge.com WWW: www.mtlsurge.com
A A m m e e m m b b e e r r o o f f t t h h e e M M T T L L I I n n s s t t r r u u m m e e n n t t s s G G r r o o u u p p p p l l c c
M M A A 1 1 5 5 t t e e c c h h n n i i c c a a l l d d a a t t a a
IEC category/VDE requirement class:
Nominal voltage U n :
Max. continuous operating voltage U c :
Max. load current I L /40°C:
Leakage current to PE at U n :
Nominal discharge surge current I n (8/20μs):
Maximum discharge surge current I max (8/20μs):
Protection level U p :
Response time t a :
RFI attenuation (50Ω):
Maximum required backup fuse:
Temperature range:
Protection type accordance to IEC 60 529/EN 60 529:
Inflammability class in accordance with UL94:
Stripping length:
Thread/Torque:
Approvals:
M M A A 1 1 5 5 S S e e r r i i e e s s
sym/asym
sym/asym
sym/asym
sym/asym
O = Remote contacts not present
R = Remote contacts present
1 = 1 module width
2 = 2 module widths
4 = 4 module widths
120 = operating voltage
230 = operating voltage
45 = 45kA surge rating
MA31 = (Product range name)
M M A A 1 1 5 5 D D 1 1
III
120V AC
150V
15A
<0.3mA
3kA/6kA
18kA/36kA
400V/400V
<1ns/<5ns
-55dB @ 100MHz -55dB @ 100MHz
15A
-40°C to +85°C
IP20
V2
8mm
M3/0.8Nm
Hazardous locations Class I Div 2
Groups A, B, C and D
M M A A 1 1 5 5 D D 2 2
III
230V AC
275V
15A
<0.3mA
3kA/6kA
18kA/36kA
1,000V/1,000V
<1ns/<5ns
15A
-40°C to +85°C
IP20
V2
8mm
M3/0.8Nm
F F i i g g u u r r e e 2 2 C C l l a a s s s s I I I I I I M M A A 1 1 5 5 d d i i m m e e n n s s i i o o n n s s