GLX60 SOLA HEVI DUTY, GLX60 Datasheet - Page 18

Enclosure Kit For The GL60

GLX60

Manufacturer Part Number
GLX60
Description
Enclosure Kit For The GL60
Manufacturer
SOLA HEVI DUTY
Series
GLr
Datasheet

Specifications of GLX60

Kit Contents
Enclosure With Mounting Screws
Product
Kits
Commercial/medical
Both
Output Power Rating
60 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 300 VDC
Mounting Style
Screw
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The GL Compact Series combines both medical and
non-medical approvals into one unit. These models offer
very high reliability, high effi ciency, active Power Factor
Correction, compact size and very low ground leakage
current.
Each model of GL100-M and GL200-M series complies with
the medical and ITE safety standards, enabling it to be used
for both medical or non-medical standard applications.
Specifications
158
GL Compact Series: Single Output Switchers
Power
Adjustment Range on
Main Output
Fan Output
Hold-up Time
Overload
Overvoltage Protection
Power Failure
Remote Sense
Temperature
Electromagnetic
Susceptibility
Humidity
Vibration
MTBF
Safety
Input Voltage
Frequency
Inrush Current
Efficiency
EMI/RFI
Power Factor
Safety Ground
Leakage Current
4
Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Open collector logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted
100 W convection (80 W for GLS102-M)
Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection
10 ms @ 150 W load, 120 Vac input
contact Technical Services at (800) 377-4384 with any questions.
GL100-M Series
Short circuit protection on all outputs. Case overload protected @ 110-160% above rating
Power Supplies
>550,000 hours demonstrated at full load, and 25°C ambient conditions
Visit our website at www.solahd.com or
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing 10% to 95% RH
IEC/EN/UL 60950-1, IEC/EN/UL 60601-1
Logical Control
IEC68-2-6 to the levels of IEC721-3-2
±10% minimum on the main outputs
275 uA @ 50/60 Hz, 264 Vac input
General
Input
15-35% above nominal output
50 A max., cold start @ 25°C
90 - 264 Vac; 120 - 300 Vdc
Output
12 V @ 1 A isolated, ±5%
88% typical at full load
Features:
• Medical Approvals
• Smaller Size
• Dual Rating
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Extensive safety approvals
• Two year limited warranty
0.99 typical
47-63 Hz
16 ms @ 250 W load, 120 Vac input
125 W for convection; 200W
GL200-M Series