TEP-HS1 TRACOPOWER, TEP-HS1 Datasheet - Page 3

HEAT SINK

TEP-HS1

Manufacturer Part Number
TEP-HS1
Description
HEAT SINK
Manufacturer
TRACOPOWER
Datasheet

Specifications of TEP-HS1

Accessory Type
Heatsink
For Use With
TEP 75WI Series DC/DC Converters
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Output Specifications
Capacitive load
General Specifications
Temperature ranges
Thermal impedance
Derating
Over temperature protection
Thermal shock
Humidity (non condensing)
Reliability, calculated MTTF (MIL-HDBK-217F, @+25°C, ground benign)
Isolation voltage (60sec.)
Isolation capacitance
Isolation resistance
Switching frequency
Safety standards
Safety approvals
Remote On/Off
Environmental compliance
Application note:
www.tracopower.com/products/tep75wi-application.pdf
– Operating
– Case temperature
– Storage
– without Heatsink
– with Heatsink
– Input/Output
– Input/Case
– Input/Output
– Input/Output (500 VDC)
– UL/cUL
– positive logic (standard)
– negative logic (option -N)
– Off idle current:
– Reach
– RoHS
24 VDC models: 1‘330 µF max.
28 VDC models: 960 µF max.
48 VDC models: 330 µF max.
12 VDC models: 5‘250 µF max.
15 VDC models: 3‘330 µF max.
5 VDC models: 30‘000 µF max.
– Off: 0 to 1.2 VDC or short circuit pin 1 and 3
– Off: 3 to 12 VDC or open circuit
– On: 3 to 12 VDC or open circuit
– On: 0 to 1.2 VDC or short circuit pin 1 and 3
–40°C to +75°C
+105°C max.
–55°C to +125°C
6.7°C/W
4.7°C/W
see derating graps page 4
at +115°C
acc. MIL-STD-810F
95 % rel H max.
75‘000 h
2’250 VDC (basic insulation)
1’500 VDC
2500 pF max.
>1 GOhm min.
300 kHz typ. (puls width modulation)
UL 60950-1 , IEC/EN 60950-1
www.ul.com
3 mA
www.tracopower.com/products/tep75wi-reach.pdf
RoHS directive 2002/95/EC
DC/DC Converters
TEP 75WI Series
-> certifications -> File E188913
Page 3 of 6
75 Watt