AEH130PS12 XP POWER, AEH130PS12 Datasheet

PSU, DESKTOP 130W 12V

AEH130PS12

Manufacturer Part Number
AEH130PS12
Description
PSU, DESKTOP 130W 12V
Manufacturer
XP POWER
Datasheet

Specifications of AEH130PS12

Power Supply Output Type
Fixed
Power Rating
130W
Input Voltage
90VAC To 264VAC
Supply Voltage Typ
110VAC / 230VAC
Output Voltage
12V
Output Current
10.8A
Connector Type
8 Pin DIN
Mounting Type
Desktop
Output Connector
8 Pin
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
45-130 Watts
AEH Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • <0.5 mA max at 115 VAC/60 Hz
Output Voltage
Initial Set Accuracy
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 112-132% Vnom, auto reset
Overload Protection
Temperature
Coefficient
• 90-264 VAC
• 47-63 Hz
• 1.5/0.7 A for AEH45, at 115/230 VAC
• AEH45 & 80: 30 A max at 230 VAC
• EN61000-3-2 class A
• See tables. Factory set non-standard
• 5%
• 2 s max
• 16 ms min (>50 ms AEH130)
• See note 2
• See note 2
• 4% max deviation, recovery to within
• 2% pk-pk for outputs ≤3.3 V
• Output 1 only 110-150% of nominal
• ±0.04%/°C max
1.9/1.5 A for AEH80, at 115/230 VAC
3.2/1.7 A for AEH130, at 115/230 VAC
AEH130: 60 A max at 230 VAC
cold start
<0.75 mA max at 230 VAC/50 Hz
voltages available - contact sales
1% in 4 ms for a 50% load change
1% pk-pk for all other outputs
20 MHz BW
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
MTBF
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
Operating Humidity
Storage Temperature
Vibration
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
Output Voltages from 2.5 V to 48 V
Non-standard Outputs Available
Universal Input
Single & Multiple Output Versions
0 °C to +70 °C Operating Temperature
Efficiency up to 80%
Non-standard Connectors Available
• Up to 80%
• 3000 VAC Input to Output
• 67-83 kHz for AEH45
• 100 kHrs per MIL-HDBK-217F
• 5-95% RH, non-condensing
• -40 °C to +85 °C
• 2 g on 3 axes
• EN55022 level B, conducted and radiated
• EN61000-3-2, Class A
• EN61000-3-2
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11 30% 10 ms,
• EN60950-1, UL60950-1,
1500 VAC Input to Ground
500 VAC Output to Ground
58 kHz typical for AEH80
53-76 kHz for AEH130
load at +40 °C to 50% load at +70 °C
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
CSA C22.2 No. 950 per cUL, CE Mark
xppower.com

Related parts for AEH130PS12

AEH130PS12 Summary of contents

Page 1

Watts AEH Series Specification Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 1.5/0.7 A for AEH45, at 115/230 VAC 1.9/1.5 A for AEH80, at 115/230 VAC 3.2/1.7 A for AEH130, at 115/230 VAC ...

Page 2

Models and Ratings Output 1 (1,2) Output Power Current Voltage Max Nom. Min Max 20 W 2.5 V 0 3.3 V 0 5.0 V 0 ...

Page 3

Models and Ratings Output 1 (1,2) Output Power Current Voltage Max Nom. Min Max 50 W 3.3 V 0 5.0 V 0 7.0 V 0 ...

Page 4

... V 0 +24 Input IEC 320-C14 Inlet 3.46 (88.0) AEH130 Output 2 (1,2) Current Total Number Regulation Min Max AEH130PS3V3 AEH130PS05 AEH130PS07 AEH130PS09 AEH130PS12 AEH130PS15 AEH130PS18 AEH130PS24 AEH130PS28 AEH130PS36 AEH130PS48 AEH130PS54 2 AEH130PD01 2 AEH130PD02 2 AEH130PD03 2 AEH130PD04 PIN CONNECTIONS Pin SINGLE Shell ...