AED70US15 XP POWER, AED70US15 Datasheet

PSU, EXT, PLUG-IN, 15V, 69W

AED70US15

Manufacturer Part Number
AED70US15
Description
PSU, EXT, PLUG-IN, 15V, 69W
Manufacturer
XP POWER
Datasheet

Specifications of AED70US15

Power Supply Output Type
Fixed
Power Rating
69W
Input Voltage
90V AC To 264V AC
Output Voltage
15V
Output Current
4.6A
Output Connector
Barrel Plug
Power Supply Mounting
Desktop
Output Type
Fixed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
36-100 Watts
AED Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current • AED36: Class II
Power Factor
Output Voltage
Initial Set Accuracy
Minimum Load
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection • Typical 125% max
Overload Protection
Short Circuit Protection • Continuous
Temperature
Coefficient
• 90-264 VAC
• 47-63 Hz
• AED36: 1.00 A max
• AED36: 50 A max at 230 VAC
• Compliant with EN61000-3-2
• See tables
• ±2%
• No minimum load requirement
• AED36: 8 ms min at 115 VAC
• ±1%
• See tables
• 1% pk-pk max, 20 MHz BW (see note 2)
• 120-150% hiccup/trip & restart mode
• ±0.04%/˚C
AED70: 1.85 A max
AED100: 2.00 A max
AED45: 100 A max at 230 VAC
AED70: 100 A max at 230 VAC
AED100: 100 A max at 230 VAC
AED45: 1.5 mA max
AED70: 1.5 mA max
AED100: 1.5 mA max
AED45: 8 ms min at 115 VAC
AED70: 8 ms min at 115 VAC
AED100: 20 ms typical at 115 VAC
with auto recovery
AED45: 1.20 A max
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
MTBF
Operating Temperature • 0 ˚C to +65 ˚C
Storage Temperature
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Safety Approvals
Low Profile
Single Outputs from 5 V to 48 V
Universal Input
Optional Floating Output
High Power Density
36, 45, 70 & 100 W Versions
Class II Insulation on 36 W Version
• 85% typical at 230 VAC & 100% load
• 3000 VAC Input to Output,
• 60 kHz ±10 kHz
• 100,000 Hrs to MIL-HDBK-217E
• -20 ˚C to +85 ˚C
• CISPR22 Level B (EN55022)
• EN61000-4-2,
• EN61000-4-3, 3 V/m
• EN61000-4-4, level 2
• EN60950-1, UL60950-1,
1500 VAC Input to Ground.
Negative output is connected to ground.
For optional 500 VAC output to ground
isolation add suffix ‘-F’ to model number
AED36, AED45 & AED70 derate
linearly from 100% load at +40 ˚C to
50% load at +55 ˚C,
AED100 derate linearly from
100% load at +40 ˚C to 0% at +65 ˚C
FCC 20780 Level B
8 kV air
4 kV contact
Perf Criteria A
Perf Criteria A
Perf Criteria A
CAN/CSA C22.2 No. 60950 cUL
xppower.com

Related parts for AED70US15

AED70US15 Summary of contents

Page 1

Watts AED Series Specification Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • AED36: 1.00 A max AED45: 1.20 A max AED70: 1.85 A max AED100: 2.00 A max Inrush Current • AED36: 50 ...

Page 2

... AED36US24 ±2% AED36US48 ±6% AED45US05 ±5% AED45US12 ±3% AED45US15 ±2% AED45US18 ±2% AED45US19 ±2% AED45US24 ±2% AED45US48 ±5% AED70US12 ±3% AED70US15 ±2% AED70US18 ±2% AED70US19 ±2% AED70US24 ±2% AED70US48 ±4% AED100US12 ±4% AED100US15 ±2% AED100US18 ±2% AED100US19 ±2% AED100US24 ±2% AED100US48 ...