AED45US18 XP POWER, AED45US18 Datasheet

PSU, EXT, PLUG-IN, 18.5V, 45W

AED45US18

Manufacturer Part Number
AED45US18
Description
PSU, EXT, PLUG-IN, 18.5V, 45W
Manufacturer
XP POWER
Datasheet

Specifications of AED45US18

Power Supply Output Type
Fixed
Power Rating
45W
Input Voltage
96V AC To 264V AC
Output Voltage
18.5V
Output Current
2.5A
Output Connector
Barrel Plug
Power Supply Mounting
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
36-100 Watts
AED Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current • AED36: Class II
Power Factor
Output Voltage
Initial Set Accuracy
Minimum Load
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection • Typical 125% max
Overload Protection
Short Circuit Protection • Continuous
Temperature
Coefficient
• 96-264 VAC
• 47-63 Hz
• AED36: 1.00 A
• AED36: 50 A max at 230 VAC
• Compliant with EN61000-3-2
• See tables
• ±2%
• No minimum load requirement
• AED36: 8 ms min at 115 VAC
• ±1%
• See tables
• 1% pk-pk max
• 120-150% hiccup / trip and restart mode
• ±0.04% /˚C
AED70: 1.85 A
AED100: 2.00 A
AED45: 100 A max at 230 VAC
AED70: 100 A max at 230 VAC
AED100: 100 A max at 230 VAC
AED45: 1.5 mA max
AED70: 1.5 mA max
AED100: 1.5 mA max
AED45: 8 ms min at 115 VAC
AED70: 8 ms min at 115 VAC
AED100: 20 ms typical at 115 VAC
with auto recovery
AED45: 1.20 A
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
MTBF
Operating Temperature • 0 ˚C to +65 ˚C
Storage Temperature
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Safety Approvals
Low Profile
Low Cost
Universal Input
Optional Floating Output
High Power Density
36, 45, 70 & 100 W Versions
International Safety Approvals
• 85% typical
• 3000 VAC Input to Output,
• 60 kHz ±10 kHz
• 100,000 hours MIL-HDBK-217E
• -20 ˚C to +85 ˚C
• CISPR22 Level B (EN55022)
• EN61000-4-2,
• EN61000-4-3, 3 V/m
• EN61000-4-4, level 2
• EN60950
2000 VAC Input to Ground.
Negative output is connected to
ground. For optional 500 VAC
output to ground isolation add
suffix “-F” to model number
AED36, AED45 and AED70 derate
linearly from 100% load at 40 ˚C to
50% load at +55 ˚C,
AED100 derate linearly from
100% load at +40 ˚C to 0% at 65 ˚C
FCC 20780 Level B
8 kV air
4 kV contact
Perf Criteria B
Perf Criteria B
Perf Criteria B
UL1950
CSA C22.2 No. 234 cUL
xppower.com

Related parts for AED45US18

AED45US18 Summary of contents

Page 1

Watts AED Series Specification Input Input Voltage • 96-264 VAC Input Frequency • 47-63 Hz Input Current • AED36: 1.00 A AED45: 1.20 A AED70: 1.85 A AED100: 2.00 A Inrush Current • AED36 max at 230 ...

Page 2

... Output cable is 48” (1.22m). AED Series Load Model (1) Regulation Number ±6% AED36US05 ±5% AED36US09 ±5% AED36US12 ±5% AED36US13 3% AED36US15 2% AED36US18 2% AED36US24 2% AED36US48 ±6% AED45US05 5% AED45US12 3% AED45US15 2% AED45US18 2% AED45US18 2% AED45US24 2% AED45US48 5% AED70US12 * 3% AED70US15 * 2% AED70US18 * 2% AED70US19 * 2% AED70US24 * 2% AED70US48 * 5% AED100US12 †* 3% AED100US15 †* 2% AED100US18 †* ...