QUS25-096-NHDR Murata Power Solutions Inc, QUS25-096-NHDR Datasheet - Page 2

DC/DC Converter

QUS25-096-NHDR

Manufacturer Part Number
QUS25-096-NHDR
Description
DC/DC Converter
Manufacturer
Murata Power Solutions Inc
Series
QUSr
Datasheet

Specifications of QUS25-096-NHDR

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
36V To 55V
Power Rating
240W
Output Voltage
9.6V
Output Current
25A
Supply Voltage
48V
Dc / Dc Converter Case Style
Quarter Brick
Product
Isolated
Output Power
240 W
Input Voltage Range
36 V to 55 V
Number Of Outputs
1
Output Voltage (channel 1)
9.6 V
Output Current (channel 1)
25 A
Isolation Voltage
2 KV
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
www.murata-ps.com
ELECTRICAL SPECIFICATIONS
Specifications typical at T
COMMON SPECIFICATIONS
Specifications typical at T
PARAMETER
HL02R05S05YC
HL02R05S12YC
HL02R05S15YC
HL02R12S05YC
HL02R12S12YC
HL02R12S15YC
HL02R15S05YC
HL02R15S12YC
HL02R15S15YC
HL02R24S05YC
HL02R24S12YC
HL02R24S15YC
HL02R05D12YC
HL02R05D15YC
HL02R12D12YC
HL02R12D15YC
HL02R15D12YC
HL02R15D15YC
HL02R24D12YC
HL02R24D15YC
INPUT
Voltage Range
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
5V Output -- Singles Only
Line Regulation
Load Regulation
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. F
Ground Benign
TEMPERATURE
Specification
Operation
Storage
MODEL
Note: Other input to output voltages may be available. Please contact factory.
NOMINAL
VOLTAGE
A
A
= +25°C, nominal input voltage, rated output current unless otherwise specified.
INPUT
= +25°C, nominal input voltage, rated output current unless otherwise specified.
(VDC)
12
12
12
15
15
15
24
24
24
12
12
15
15
24
24
5
5
5
5
5
VOLTAGE
OUTPUT
RATED
(VDC)
±12
±15
±12
±15
±12
±15
±12
±15
Rated Load to No Load
12
15
12
15
12
15
12
15
High Line to Low Line
Circuit Stress Method
5
5
5
5
V
BW = DC to 10MHz
BW =10Hz to 2MHz
60 Hz, 10 Seconds
ISO
CONDITIONS
= 240VAC, 60Hz
T
T
A
A
= +25°C
= +70°C
CURRENT
OUTPUT
RATED
(mA)
±83
±67
±83
±67
±83
±67
±83
±67
400
166
134
400
166
134
400
166
134
400
166
134
MIN LOAD
(mA)
14.25
11.4
22.8
MIN
500
500
4.75
-25
-40
-40
70
70
70
40
40
40
30
30
30
15
15
15
70
70
40
40
30
30
15
15
INPUT CURRENT
RATED LOAD
(mA)
±0.02
1100
±0.5
±0.5
±0.5
640
580
580
280
250
250
230
200
200
135
120
120
640
640
270
270
220
220
135
135
250
110
TYP
12
15
24
30
25
25
10
12
20
5
1
2
2
Technical enquiries email: sales@murata-ps.com, tel:
2 W
EFFICIENCY
ATT
15.75
+110
MAX
12.6
25.2
±1
±1
(%)
100
100
350
+70
+85
62
69
69
60
67
67
58
67
67
62
67
67
62
62
62
62
61
61
62
5.25
62
±5
R
EGULATED
TDC_HL02RYC.B02 Page 2 of 3
mVrms
mAp-p
μArms
mVp-p
UNITS
mVp-p
DC/DC C
%/°C
VDC
VDC
VDC
VDC
VDC
Vpk
kHz
G
kHr
kHr
pF
°C
°C
°C
W
%
%
%
HL02RYC
g
+1 508 339 3000
ONVERTER

Related parts for QUS25-096-NHDR