UEI-3.3/15-Q12NR-C Murata Power Solutions Inc, UEI-3.3/15-Q12NR-C Datasheet - Page 9

CONVERTER, DC/DC, 3.3V, 15A

UEI-3.3/15-Q12NR-C

Manufacturer Part Number
UEI-3.3/15-Q12NR-C
Description
CONVERTER, DC/DC, 3.3V, 15A
Manufacturer
Murata Power Solutions Inc

Specifications of UEI-3.3/15-Q12NR-C

No. Of Output Channels
1
Input Voltage
9V To 36V
Power Rating
49.5W
Output Voltage
3.3V
Output Current
15A
Supply Voltage
24V
Dc / Dc Converter Case Style
Through Hole
Isolation Voltage
2.25kV
Product
Isolated
Output Power
50 W
Input Voltage Range
9 V to 36 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
15 A
No. Of Outputs
1
Approval Bodies
CSA / EN / UL
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
OVP circuit may inadvertantly shut down the converter. If the maximum power
is exceeded, the converter may enter current limiting. If the power is exceeded
for an extended period, the converter may overheat and encounter overtem-
perature shut down.
input to the converter’s feedback control loop. Excessive electrical noise may
cause instability or oscillation. Keep external connections short to the Trim
input. Use shielding if needed. Also consider adding a small value ceramic
capacitor between the Trim and –V
tor tolerances and factory-adjusted output accuracy. Mount trim resistor close
to converter. Use short leads.
Remote On/Off Control
On the input side, a remote On/Off Control can be ordered with either polarity.
Trim Equations
Figure 7 – Trim adjustments to increase Output Voltage using a Fixed Resistor
CAUTION: Be careful of external electrical noise. The Trim input is a senstive
Where Vo = Desired output voltage. Adjustment accuracy is subject to resis-
R
R
R
R
T
T
T
T
UP
UP
UP
UP
between Trim and –Sense>
() =
() =
() =
() =
2
4
1
<Connect trim resistor
CONTROL
+INPUT
ON/OFF
Trim Up
INPUT
V
V
V
12775
25000
25000
O
12775
V
O
O
– 3.3
O
– 12
– 15
– 5
UEI-3.3/15-Q12, -3.3/18-Q48
UEI-12/4.2-Q12, -12/5-Q48
UEI-5/10-Q12, -5/12-Q48
– 2050
– 2050
– 5110
– 5110
UEI-15/3.3-Q12, -Q48
+OUTPUT
+SENSE
OUTPUT
SENSE
TRIM
out
to bypass RF and electrical noise.
R
R
R
R
T
T
T
T
R
6
5
9
8
7
DOWN
DOWN
DOWN
DOWN
TRIM UP
between Trim and +Sense>
<Connect trim resistor
() =
() =
() =
() =
www.murata-ps.com
Trim Down
5110 (Vo - 2.5)
5110 (Vo - 2.5)
10000 (Vo-2.5)
10000 (Vo-2.5)
3.3 – V
12 – V
15 – V
5 – V
O
O
O
O
LOAD
– 2050
– 2050
–5110
–5110
is pulled high to +V
open pin to rise to +V
voltages (see Specifications). Positive-polarity devices are disabled when the
On/Off is grounded or brought to within a low voltage (see Specifications) with
respect to –V
Off is grounded or brought to within a low voltage (see Specifications) with
respect to –V
pulled high to +15V
signal current when brought low and withstand appropriate voltage when
brought high. Be aware too that there is a finite time in milliseconds (see
Specifications) between the time of On/Off Control activation and stable,
regulated output. This time will vary slightly with output load type and current
and input conditions.
input side ONLY. If you must control it from circuits in the output, use some
form of optoisolation to the On/Off Control. This latter condition is unlikely
because the device controlling the On/Off would have to remain powered on
and not be powered from the converter.
Positive: Standard models are enabled when the On/Off pin is left open or
Negative: Optional negative-polarity devices are on (enabled) when the On/
Dynamic control of the On/Off function should be able to sink appropriate
There are three CAUTION’s for the On/Off Control:
CAUTION: To retain full output circuit isolation, control the On/Off from the
50-60W Isolated Wide-Range DC/DC Converters
Figure 9 – Driving the Negative Polarity On/Off Control Pin
Figure 8 – Driving the Positive Polarity On/Off Control Pin
in
in
.
. The device is off (disabled) when the On/Off is left open or is
in
dc
Technical enquiries email: sales@murata-ps.com, tel:
with respect to –V
in
Max. with respect to –V
. Some models will also turn on at lower intermediate
4
2
4
2
CONTROL
−INPUT
ON/OFF
CONTROL
−INPUT
ON/OFF
MDC_UEI Series 50-60W.B16 Page 9 of 10
in
. An internal bias current causes the
in
.
UEI Series
+1 508 339 3000

Related parts for UEI-3.3/15-Q12NR-C