UCP-12/5-D24 Murata Power Solutions Inc, UCP-12/5-D24 Datasheet
UCP-12/5-D24
Specifications of UCP-12/5-D24
Related parts for UCP-12/5-D24
UCP-12/5-D24 Summary of contents
Page 1
... The high effi ciency, low noise and long-term reliability that defi nes DATEL DC/DC Converters now comes to you in the standard "half-brick" confi guration (2.3" x 2.4" x 0.52"). All models in our new UCP Series meet UL/EN60950 safety require- ments, including each European country’s deviations Test Certifi cate/Report is available. All models have BASIC insulation ...
Page 2
... OBSOLETE UCP-5/10-D12 5 10 OBSOLETE UCP-5/12-D24 5 12 TARGETED UCP-5/12-D48 5 12 OBSOLETE UCP-5/15-D48 5 15 OBSOLETE UCP-12/4.2-D12 12 4.2 TARGETED UCP-12/5-D24 12 5 TARGETED UCP-12/5-D48 12 5 TARGETED UCP-15/3.3-D12 15 3.3 TARGETED UCP-15/4-D24 15 4 TARGETED UCP-15/4-D48 NRND ➀ Typical +25°C under nominal line voltage and full-load conditions unless otherwise noted. ...
Page 3
... Volts, limited duration 18 Volts, limited duration Current limited. 12/15V devices can withstand an output short circuit for a brief duration only. 3.3/5V devices can withstand output shorts indefi nitely. –40 to +105°C +300°C Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCP40-75W.B03 Page ...
Page 4
... Figure 3b. Temperature Derating With HS-CP Heat Sink Natural Convection Cooling 150 Linear Feet Per Minute 300 Linear Feet Per Minute Ambient Temperature (°C) Figure 4b. Temperature Derating With HS-CP Heat Sink Technical enquiries email: sales@murata-ps.com, tel: MDC_UCP40-75W.B03 Page 100 100 100 +1 508 339 3000 ...
Page 5
... As shown in Figure 5, the control pin is referenced to the –Input (pin 1) and has an internal pull-up resistor (28.7k: 75k: and 100k: respectively for D12, D24 and D48 models) to the +Input (pin 4). The standard UCP converter is designed so that it is enabled when the control pin is left open and disabled when the control pin is pulled low (to less than +0.8V relative to – ...
Page 6
... If you are using both the external Trim and Sense functions, you must not attempt to force the converter output voltage more than 5% above its initial, "untrimmed" value. When UCP DC/DC Converters are tested for output accuracy during fi nal test, the Sense pins are connected directly to their respective output pins. Case Connection Unlike most other DC/DC converters, UCP DC/DC's do not have their metal case connected to one of their input pins. The " ...
Page 7
... Both models are shipped with 0.009" sellf-adhesive thermal pad and mounting screws. Note: When mounting the heat sink to the UCP converter: 1. Maximum applied torque is 2 in-lbs. 2. Minimum thread engagement of the mounting screws is 12mm deep. ...