PH100F24-24 TDK Corporation, PH100F24-24 Datasheet - Page 44

DC/DC Converter

PH100F24-24

Manufacturer Part Number
PH100F24-24
Description
DC/DC Converter
Manufacturer
TDK Corporation
Datasheet

Specifications of PH100F24-24

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
100W
Output Voltage
24V
Output Current
4.2A
Approval Bodies
UL, CSA, CE
Supply Voltage
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PH100F24-24
Manufacturer:
VICOR
Quantity:
101
Part Number:
PH100F24-24
Manufacturer:
LAMBDA
Quantity:
37
Part Number:
PH100F24-24
Quantity:
60
PH
B-342
(a)N+1 Redundant connection
(b)Redundant Operation with programmed output voltage
(c)Redundant operation with adjustable output voltage
PH
4 N+1 REDUNDANT OPERATION
Confirm the following items before you think the module is
damaged or failed.
1)No Output
2)High Output Voltage
● Is the rated input voltage supplied?
● Are the ON/OFF control terminal, remote sensing
● For adjusted output, is the variable resistor network
● Is there any troubles with the connected load?
● Is the remote sensing connected correctly?
● For adjusted output, is the variable resistor network
50 - 150, 75 - 300F
terminal, and output volatage trimming terminal con-
nected correctly?
set up and connected correctly?
set up and connected correctly?
Figure4-2: N+1 Redundant Operation with
Figure4-1: N+1 Redundant Operation
4. Before You Think The Module is damaged
TRM
TRM
+S
+V
−V
−S
+S
+V
−V
−S
PC
PC
+S
+V
−V
−S
+S
+V
−V
−S
PC
PC
programmed output voltage
LOAD
LOAD
(d)Redundant operation when the output voltage is ad-
3)Low Output Voltage
4)Over Load Regulation or Over Input Regulation
5)High Output Ripple
Figure4-4 : N+1 Redundant Operation which is possible to
Note) Please do sufficient evaluation on actual products when
adjust the output voltage by external applied voltage
● Is the rated input voltage supplied?
● Is the remote sensing connected correctly?
● Is it measured at sensing point?
● For adjusted output, is the variable resistor network
● Is there any troubles with the connected load?
● Is the rated input voltage supplied?
● Are the input and output terminals connected correct-
● Is it measured at sensing point?
● Are input and output wires too thin?
● Is it same measuring meathod as the instruction
● Is the input ripple voltage within the specification?
justed by applying voltage externally
set up and connected correctly?
ly?
manual?
applying N+1 redundant or parallel operation.
Figure4-3 : N+1 Redundant Operation with
TRM
TRM
+S
+V
−V
−S
+S
+V
−V
−S
TRM
TRM
PC
PC
+S
+V
−V
−S
+S
+V
−V
−S
PC
PC
adjustable output voltage
・All specifications are subject to change without notice.
LOAD
LOAD