BCP-5/15-3.3/15-D24-C Murata Power Solutions Inc, BCP-5/15-3.3/15-D24-C Datasheet - Page 6

DC/DC Converter

BCP-5/15-3.3/15-D24-C

Manufacturer Part Number
BCP-5/15-3.3/15-D24-C
Description
DC/DC Converter
Manufacturer
Murata Power Solutions Inc
Series
BCPr
Datasheet

Specifications of BCP-5/15-3.3/15-D24-C

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
2
Input Voltage
18V To 36V
Power Rating
50W
Output Voltage
5V
Output Current
15A
Output Voltage 2
3.3V
Output Current 2
15A
Supply Voltage
24V
Product
Isolated
Output Power
75 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Number Of Outputs
2
Output Voltage (channel 1)
5 V
Output Current (channel 1)
15 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
15 A
Isolation Voltage
1.5 KV
Package / Case Size
Half Brick
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Overvoltage Protection
Each voltage output of the BCP Series converter is independently moni-
tored via an auxiliary winding in the output inductor. If the output voltage
should rise to a level which could be damaging to the load circuitry (see
Performance/Functional Specifi cations for limits), the overvoltage circuitry
will power down the PWM controller and latch off the DC/DC converter. The
device must now be restarted by powering cycling V
Current Limiting
When output current demands exceed the maximum output current rating
by 107% to 133%, the DC/DC converter will go into a current limiting
mode. In this condition the output voltage decreases proportionately as the
output current increases, thereby maintaining a somewhat constant power
dissipation—referred to as Power Limiting (see Figure 2). As the load
approaches a short circuit, the output current will continue to increase until
it reaches the rated Short Circuit Current limit.
Short Circuit Condition
As described under "Current Limiting," when the BCP Series DC/DC converter
output is subjected to a short circuit condition, the output current will remain at
the Short Circuit Current limit. In this state there is negligible power dissipated
in the load. Therefore, most of the input power is dissipated within the con-
verter, causing the internal temperature to increase. If this condition persists,
Thermal Shutdown will activate and shutdown the DC/DC converter. When the
internal temperature is suffi ciently decreased, the converter will self-start.
Thermal Shutdown
The BCP Series is equipped with Thermal Shutdown circuitry. If the internal
temperature of the DC/DC converter rises above the designed operating tem-
perature, a precision temperature sensor will power down the unit. When the
internal temperature decreases below the threshold of the temperature sensor
the unit will self-start.
6.00
5.00
4.00
3.00
2.00
1.00
0
BCP-5/15-3.3/15-D24, D48 Current Limiting Characteristics
(Nominal V
IN
)
Figure 2. Current Limiting Characteristics
3.3V Output
Output Current, I
OUT
5V Output
(Amps)
IN
.
www.murata-ps.com
Input Reverse-Polarity Protection
Upon applying a reverse-polarity voltage to the DC/DC converter, an internal
diode will be forward biased and draw excessive current from the power
source. Therefore, it is required that the input current be limited be either an
appropriately rated input fuse or a current limited power source.
Heat Sinks for BCP Series
MPS offers two standard heat sinks that can be mounted to the half-brick
package to extend the converter's operating temperature range. Along with the
standard 2.3" x 2.4" x 0.5" (HS-CP) heat sink, DATEL has designed a low-profi le
heat sink for height-restricted applications. This new heat sink (HS-CPLP2) is
designed with radiant fi ns that extend 0.51" beyond either side of the 2.4"
dimension of the BCP package. The convenience of this design is that the fi nned
extensions protrude only 0.31" below the top surface of the DC/DC converter,
allowing components with a profi le height less than 0.215" to be mounted on
the pc board below the heat sink. Therefore, while the surface area of the low-
profi le heat sink measures 2.3" x 3.5", pcb real estate is unaffected.
low-profi le heat sink should be mounted with the fi ns vertically oriented. Both
models are shipped with 0.009" sellf-adhesive thermal pad and mounting
screws.
For optimum thermal performance in a natural convection application, the
6
5
4
3
2
1
0
0
HS-CP and HS-CPLP2 Heat Sink Performance Vs. Air Flow
Dual Output, Mixed Voltage, Isolated 5V & 3.3 V,
100
(@ 10.5 Watts Power Dissipation)
200
HS-CP
"Half-Brick" 75 W DC/DC Converters
AIR VELOCITY (FT./MIN.)
300
12 Nov 2009 MDC_BCP_75W.B03 Page 6 of 14
400
HS-CPLP2
BCP Models
email: sales@murata-ps.com
500
600
700

Related parts for BCP-5/15-3.3/15-D24-C