QPX1200SP AIM-TTI INSTRUMENTS, QPX1200SP Datasheet - Page 3

no-image

QPX1200SP

Manufacturer Part Number
QPX1200SP
Description
PSU, 1.2KW WITH LXI 60V 50A MAX
Manufacturer
AIM-TTI INSTRUMENTS
Datasheet

Specifications of QPX1200SP

Power Supply Output Type
Variable
No. Of Output Channels
1
Output Voltage
60V
Output Current
50A
Power Rating
1.2kW
Input Voltage
110VAC To 240VAC
Supply Voltage Typ
110VAC / 230VAC
Load
RoHS Compliant
No. Of Outputs
1
Rohs Compliant
NA
Graphic display for clarity and ease of use
The QPX600D incorporates two
high resolution graphic LCDs
capable of showing numbers and
text in a variety of sizes.
The standard display mode shows
voltage and current in large characters along with text annunciators such as
CV mode and Output On.
More complex functions are
provided with text prompts or
complete selection menus.
Current meter averaging
When measuring rapidly varying loads it can become difficult to get useful
readings from the current meter.
By selecting meter averaging, the reading is stabilised by averaging the last
four readings to reduce the speed and extent of the variation.
Numeric or rotary entry
Voltage and current levels can be set directly via the numeric keypad.
Alternatively settings can be changed via the jog wheel at user selectable
increments.
Multiple settings stores
Non-volatile stores are incorporated for rapid recall of voltage and current
settings and are useful for repetitive testing applications.
Separate stores are provided for each output.
OVP and OCP trips
Variable trips for over-voltage and over-current are provided on each output.
Unlike a limit setting, the trip setting turns the output off and provides a
different level of protection.
For example, when repetitively testing a unit which normally takes a peak
current of 10A, the current limit could be set to 11A and the OCP to 10.1A to
ensure that a faulty unit will trip the supply off and not be damaged by over
dissipation.
The output trip can also be activated by other fault conditions including over
temperature and remote sense mis-wiring. The cause of the trip is shown on
the display.
Analog and Logic interfaces
The control voltages are digitised to control the PSU and the scaling can be
selected as 0 to 5V or 0 to 10V for zero to full scale.
Monitor outputs for voltage and current are also provided, and can similarly be
selected as 0 to 5V or 0 to 10V.
An opto isolated logic control signal is provided for control of output on/off.
This can be menu selected as true = output on, or true = output off.
An opto isolated open-collector logic output signal is also available. This can
be menu selected as true or false for output enabled or disabled, current limit,
power limit, or any fault trip.
Both models incorporate analog interfaces for voltage
control of both output voltage and output current
(non-isolated).
changed, a dual display of
parameters is used enabling
existing and new settings, or
actual and limit values to be
viewed simultaneously.
When settings are being
QPX1200SP & QPX1200L - USB, RS-232, LAN & GPIB
QPX1200SP - comprehensive bus remote control
To meet a wide variety of needs, the QPX1200SP adds a comprehensive
array of digital bus interfaces. RS-232, USB, GPIB and LAN (Ethernet)
with LXI support are all provided as standard.
Each of the digital bus interfaces provides full control of voltage,
current, output on/off and set-up, plus read-back of voltage, current
and status. The interfaces are at ground potential and are opto-isolated
from the output terminals.
the control of power supplies because data speed is not an issue.
which supports Windows 2000, XP , Vista and Windows 7.
Network or direct connection to a single PC. This interface supports LXI
and is highly appropriate for system use because of its scalable nature
and low cost interconnection.
the LXI Consortium, and is expected to become the successor to GPIB in
many systems. For more information on LXI and how it replaces GPIB,
or operates along side it, go to: www.tti-test.com/go/lxi
IVI Driver
An IVI driver for Windows is included. This provides support for common
high-level applications such as LabView*, LabWindows*, and HP/
Agilent VEE*.
* LabView and LabWindows are trademarks of National Instruments.
* Windows is a trademark of Microsoft.
QPX1200L
The QPX1200L is identical to the QPX1200SP but omits the GPIB
interface.
Other models in the QPX series
For those requiring only a dual output power supply, the QPX600D offers dual
outputs of 600 watts each using PowerFlex+ regulation.
Go here for details: www.tti-test.com/go/qpx
HPVEE (now Agilent VEE) is a trademark of Agilent Technologies.
USB provides a simple and convenient means of
connection to a PC and is particularly appropriate
for small system use. A USB driver is provided
The LAN interface is compliant with LXI class C. LXI
(LAN eXtensions for Instrumentation) is the next-
generation, LAN-based modular architecture
standard for automated test systems managed by
An RS-232/RS-423 interface is provided for use with
legacy systems. This type of serial interface remains
in common useage and is perfectly satisfactory for
The GPIB interface is compliant with IEEE-488.1
and IEEE-488.2. Currently GPIB remains the most
widely used interface for system applications.
The LAN interface uses a standard 10/100 base-T
Ethernet hardware connection with ICMP and
TCP/IP Protocol for connection to a Local Area

Related parts for QPX1200SP